FIN-19-057 - T19-116 Steel Pipe for Natural Gas Distribution
CityofKitchener
>
Public Access Folders
>
Reports - 01-08-003
>
FIN (April 2018-Pres)
>
2019
>
FIN-19-057 - T19-116 Steel Pipe for Natural Gas Distribution
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/21/2019 10:24:05 AM
Creation date
6/21/2019 10:24:04 AM
Metadata
Fields
Template:
Reports
Department Name
Financial Services
Date of Report
6/4/2019
Date of Meeting
6/24/2019
Document Relationships
Council Agenda - 2019-06-24
(Message)
Path:
\Public Access Folders\Agendas\Council Agendas - 02-01-031\2019
Council Minutes - 2019-06-24
(Message)
Path:
\Public Access Folders\Minutes\Council Minutes - 02-01-193\2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REPORT TO:Committee of the Whole <br />DATE OF MEETING:2019-06-24 <br />SUBMITTED BY:Margaret Fisher, Director of Procurement, 519-741-2200 ext. 7214 <br />PREPARED BY:Alex Albrecht,Associate Procurement Specialist,519-741-2200ext.7216 <br />WARD (S) INVOLVED:Wards1and2 <br />DATE OF REPORT:2019-06-04 <br />REPORT NO.:FIN-19-057 <br />SUBJECT:T19-116Steel Pipe for Natural Gas Distribution <br />__________________________________________________________________________________________ <br />RECOMMENDATION: <br />That Tender T19-116Steel Pipe for Natural Gas Distribution, be awarded to Comco Pipe <br />& Supply Company,Puslinch, Ontario, at their provisionalprice of $154,512.00,plus <br />H.S.T. of $20,086.56, for a total of $174,598.56. <br />BACKGROUND: <br />The past winter sawextremesustainedtemperatures, which Kitchener has not experienced in <br />several years. As a result, of this cold weather and the growth of the demands on the distribution <br />system, primarily in the residential market, the resulting low pressures within the natural gas <br />systempresented a concern, primarily in the north-west portion of the city. <br />premises. For this to be accomplished, the diameter of some of thepipe delivering the natural <br />gas needs to be increased. The pipe that is being quoted in this request is intended to be <br />installed directly downstream of the Graber District Regulator Station, which feedsthe most <br />affected areas. The desire is that once this pipe is installed, and increasing the outlet pressures <br />from Graber Station, the minimum deliverypressures in thenorth-west portion of the citywill <br />increaseby the predicted values. <br />Additional work will need to be completed on the natural gas distribution system in subsequent <br />future years to counteract the affects of further growth within the city. <br />REPORT: <br />As per clause 170.7.3 of the Purchasing By-law 2017- <br />Value, the Director of Supply Services shall submit a report to Council recommending award of <br />a purchase greater than $100,000 if any one or more of the following conditions apply: b. the <br />***This information is available in accessible formats upon request. *** <br />Please call 519-741-2345 or TTY 1-866-969-9994forassistance. <br />1.v - 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.