HomeMy WebLinkAboutCSD-18-014 - B 2018-004 - 6 Pequegnat Ave�, Staff Report
ITc� [�.R Community Services Department wm kitchenerca
REPORT TO: Committee of Adjustment
DATE OF MEETING: January 16, 2018
SUBMITTED BY: Juliane von Westerholt, Senior Planner - 519-741-2200 ext. 7157
PREPARED BY: Brian Bateman, Senior Planner - 519-741-2200 ext. 7869
WARD: 10
DATE OF REPORT: January 8, 2018
REPORT # CSD -18-014
SUBJECT: B2018-004 - 6 Pequegnat Avenue
Applicant - CPM Construction Management Inc.
Approve with Conditions
Location Map: 6 Pequegnat Avenue
RECOMMENDATION
That Application B2018-004 requesting consent to sever the subject property into two
lots to redevelop the severed and retained lands with new purpose built single detached
dwellings, be approved, subject to the following conditions:
1. That the Owner obtains Demolition Control approval to the satisfaction of the
Director of Planning.
2. That the Owner obtains a Demolition Permit to the satisfaction of the Chief
Building Official.
3. That the Owner shall obtain a tax certificate from the City of Kitchener to verify
that there are no outstanding taxes on the subject property to the satisfaction of
the City's Revenue Division.
4. That the owner shall enter into an agreement with the City of Kitchener to be
prepared by the City Solicitor and registered on title of the severed lands which
shall include the following:
a) That the owner shall prepare a Tree Preservation/Enhancement Plan for the
severed and retained lands in accordance with the City's Tree Management
Policy, to be approved by the City's Director of Planning and where
necessary, implemented prior to any grading, tree removal or the issuance
of building permits. Such plans shall include, among other matters, the
identification of a proposed building envelope/work zone, landscaped area
and vegetation to be preserved.
b) The owner further agrees to implement the approved plan. No changes to
the said plan shall be granted except with the prior approval of the City's
Director of Planning.
5. That the Owner shall enter into an agreement with the City of Kitchener to be
prepared by the City Solicitor and registered on title of the severed and retained
lands which shall include the following:
a) That prior to any grading or the application or issuance of a building
permit, the owner shall submit a plan, prepared by a qualified consultant, to
the satisfaction and approval of the City's Director of Planning showing:
(i) the proposed location of all buildings (including accessory buildings and
structures), decks, fencing and driveways;
(ii) the location of any existing buildings or structures to be removed or
relocated;
(iii) the proposed grades and drainage;
(iv) the location of all trees to be preserved, removed or potentially impacted
on or adjacent to the subject lands, including notations of their size,
species and condition;
(v) justification for any trees to be removed; and
(vi) outline tree protection measures for trees to be preserved including city
trees #177490 (95cm Sugar Maple) and #171541 (46cm Norway Maple)
located within the Pequegnat Ave. and Mansion St. ROW.
b) Any alteration or improvement to the lands including grading, tree removal
and the application or issuance of any building permits shall be in
compliance with the approved plan. Any changes or revisions to the plan
require the approval of the City's Director of Planning.
6. That the owner pay to the City of Kitchener a cash -in -lieu contribution for park
dedication on the severed parcel equal in the amount of $7,815.40. The park land
dedication is calculated at the residential rate of 5% of the per metre lineal
frontage land value.
7. That the owner provide a digital file of the deposited reference plan(s) prepared by
an Ontario Land Surveyor in .dwg (AutoCad) or .dgn (Microstation) format, as well
as one full size paper copy of the plan(s). The digital file needs to be submitted
according to the City of Kitchener's Digital Submission Standards to the
satisfaction of the City's Mapping Technologist.
8. That the Owner make financial arrangements to the satisfaction of the City's
Engineering Division for the installation of any new service connections to the
severed and/or retained lands.
9. That the owner make financial arrangements to the satisfaction of the City's
Engineering Services for the installation, to City standards, of boulevard
landscaping including street trees, and a paved driveway ramp, on the severed
lands.
10. That any new driveways be built to City of Kitchener standards at the Owner's
expense prior to occupancy of the building to the satisfaction of the City's
Engineering Division.
11. That the Owner provide a servicing plan showing outlets to the municipal
servicing system to the satisfaction of the Director of Engineering Services.
12. That the Owner submit a complete Development and Reconstruction As -Recorded
Tracking Form (as per the Public Sector Accounting Board (PSAB) S. 3150)
together with a digital submission of all AutoCAD drawings required for the site
(Grading, Servicing etc.) with the corresponding correct layer names and
numbering system to the satisfaction of the Director of Engineering Services.
13. That the Owner provides Engineering staff with confirmation that the basement
elevation can be drained by gravity to the street sewers. If this is not the case,
then the Owner will be required to pump the sewage via a pump and forcemain to
the property line and have a gravity sewer from the property line to the street, all
at the Owner's expense, to the satisfaction of the Director of Engineering
Services.
14. That the Owner obtains a building permit for the construction of single detached
dwellings to the satisfaction of the Chief Building Official.
REPORT
Planning Comments:
The subject property is designated Low Rise Conservation -A in the City's Central Frederick
Secondary Plan and zoned Residential Five Zone (R-5) in Zoning By-law 85-1 with Special Use
Provision 129U, which prohibits 3 -unit multiple dwellings. The subject parcel of land is
described as a corner lot property, irregularly shaped with 19.4 metres of frontage onto
Pequegnat Avenue and 38.7 metres of frontage onto Mansion Street for an area of 789 square
metres. City records indicate the lands are currently developed with an existing duplex, which
has fallen into disrepair. The surrounding neighbourhood contains a mix of low rise residential
land uses, predominantly in the form of single detached dwellings and some duplex dwellings.
Staff had undertaken a site visit in May 2017 and more recently in December 2017.
In May of 2017, the Committee heard applications (B2017-010 & A2017-047/48) to sever the
subject lands with the intent to construct duplex dwellings on both the severed and retained lots.
Minor variances were also required to implement the dwelling location plans on the subject lots.
The applications were refused by the Committee.
The owner has submitted a new consent application proposing changes from the original
submission in order to address concerns expressed by neighbouring property owners and the
Committee. The new proposal is to sever a residential lot with 16.9 metres of frontage onto
Mansion Street, and due to the irregular shape of the existing lot, the depth varies from 12
metres to 21 metres and has 307 square metres of lot area. The retained lot will maintain its
current street frontage onto Pequegnat Avenue and will have 21.77 metres of flanking street
frontage onto Mansion Street and a lot area of 395 square metres. Single detached dwellings
are being proposed on each lot and variances are not required to implement the proposed
single detached dwelling building plans. The current dwelling and detached structure on the
subject lands are proposed to be demolished.
Figure 1 - Existing Dwelling (photo taken in May 2017)
Figure 2 - Location of Proposed Severed Lot
Consent Application — B2018 -004
With respect to the criteria for the subdivision of land listed in Section 51(24) of the Planning
Act, R.S.O. 1990. c.P. 13, the uses of both the severed and retained parcels are in conformity
with the Provincial Policy Statement (2014) and the City's Official Plan and comply with Zoning
By-law 85-1. In addition, both lots exceed the minimum lot width and lot area regulations of the
R-5 zone and each lot can be serviced municipally with independent service connections.
The proposed severance represents infill intensification which conforms to the Provincial Policy
Statement (2014) and the City's Official Plan (2014) and the configuration of the lots is
considered appropriate for the use of the lands. In addition, the proposed lotting fabric is
consistent with the context of the neighbourhood. Lot sizes and fabric observed within the
vicinity of the subject lands identified in the Figure 3 below, indicate that there a number of
existing lots located along Mansion Street, Chestnut Street, and Gordon Avenue of similar size
to the lots being proposed. Moreover, the owner has demonstrated that each lot can be
developed with single detached dwellings in compliance with the R-5 zoning regulations.
Figure 3 - Existing Lotting Fabric
Based on the foregoing, Planning staff recommends that this application be approved, subject
to the conditions outlined below in the Recommendation section of this report.
Building Comments:
The Building Division has no objections to the proposed consent provide the demolition permit for 6
Pequegnat Ave is obtained. Region of Waterloo and Area Municipalities' Design Guidelines and
Supplemental Specifications for Municipal Services (DGSSMS) allows only one service per
lot. Should a severance be approved, additional services will be required for severed lot. Separate
building permit(s) will also be required for the construction of the new single detached dwellings.
Heritage Comments:
Heritage Planning staff has no concerns with the application.
The Kitchener Cultural Heritage Landscape Study (CHLS) dated December 2014 and prepared
by The Landplan Collaborative Ltd. was approved by Council in 2015. The CHLS serves to
establish an inventory. The CHLS was the first step of a phased cultural heritage landscape
(CHL) conservation process. The owner of the property municipally addressed as 6 Pequegnat
Avenue is advised that the property is located within the Central Frederick Neighbourhood CHL.
The owner and the public will be consulted as the City considers listing CHLs on the Municipal
Heritage Register, identifying CHLs in the Official Plan and preparing action plans for each CHL
with specific conservation options. Please contact Michelle Drake, Senior Heritage & Policy
Planner, for more information.
Note that the subject property is located within the Central Fredrick Secondary Plan. The City
will be commencing a secondary plan review in 2018. The land use and zoning of the property
is subject to change. For more information, please contact Michelle Drake, Senior Heritage &
Policy Planner, by phone (519-741-2200 ext. 7839) or by email(michelle.drake(u-)kitchener.ca).
Environmental Planning Comments:
Standard condition to enter into an agreement registered on title of both the severed and
retained lands requiring a Tree Preservation / Enhancement Plan be submitted and approved
before a building permit issuance is required. A condition related to the protection of street
trees is required.
Transportation Services Comments:
Transportation Services has no concerns with the proposed application.
Engineering Comments:
• Severance of any blocks within the subject lands will require separate, individual service
connections for sanitary, storm, and water, in accordance with City policies.
• The owner is required to make satisfactory financial arrangements with the Engineering
Division for the installation of new ones that may be required to service this property, all
prior to severance approval. Our records indicate sanitary, storm and water municipal
services are currently available to service this property. Any further enquiries in this
regard should be directed to Niall Melanson (519-741-2200 ext. 7133).
• Any new driveways are to be built to City of Kitchener standards. All works is at the
owner's expense and all work needs to be completed prior to occupancy of the building.
• A servicing plan showing outlets to the municipal servicing system and proposed
easements will be required to the satisfaction of the Engineering Division prior to
severance approval.
• As per the Public Sector Accounting Board (PSAB) S. 3150 the Development and
Reconstruction As -Recorded Tracking Form is required to be filled out and submitted
along with a digital submission of all AutoCAD drawings required for the site (Grading,
Servicing etc.) with the corresponding correct layer names and numbering system to the
satisfaction of the Engineering Division prior to severance approval.
• The owner must ensure that the basement elevation of the building can be drained by
gravity to the street sewers. If this is not the case, then the owner would have to pump
the sewage via a pump and forcemain to the property line and have a gravity sewer from
the property line to the street.
Operations Comments:
A cash -in -lieu of park land dedication will be required on the severed parcel as a new
development lot will be created. The cash -in -lieu dedication required is $7,815.40. Park
Dedication is calculated at 5% of the new development lot only, with a land valuation calculated
by the lineal frontage (16.99m) at a land value of $9,200 per frontage metre.
The applicant is required to protect city trees #177490 (95cm Sugar Maple) and #171541 (46cm
Norway Maple) located in the Pequegnat Ave and Mansion St right-of-ways. Protection shall be
in accordance with the City's Tree By-law 87-293, Chapter 690 Articles 4 and 7. The applicant
is further required to implement the City's standard tree protection requirements to the
satisfaction of the Director of Operations, in accordance with the City's Development Manual.
Brian Bateman, MCIP, RPP Juliane von Westerholt, BES, MCIP, RPP
Senior Planner Senior Planner
Region of Waterloo
MraOrem 11113100071R3601111rr
January 8, 2018
Holly Dyson
Committee of Adjustment
City of Kitchener
P.O. Box 1118
200 King Street East
Kitchener, ON N2G 4G7
PLANNING, DEVELOPMENT
AND LEGISLATIVE SERVICES
Community Planning
150 Frederick Street 8th Floor
Kitchener Ontario N2G 4,13 Canada
Telephone: 519-575-4400
TTY: 519-575-4608
Fax: 519-575-4466
www. reg ionofwate rl oo.ca
Carolyn Crozier
575-4757 ext. 3657
Re: Comments for Consent Applications
B2018-001 to B2018-004
Committee of Adjustment Hearing January 16, 2018
CITY OF KITCHENER
B 2018-001
301 Westmount Road West
2054908 Ontario Inc. and Victoria-Vicmount Inc.
The purpose of the application is to grant easements for stormwater and sanitary
service and parking and access purposes.
Regional staff have no objection to the application.
B 2018-002
67 Second Avenue
Vlad Knezevic
The purpose of the application is to create a new lot for residential development.
Community Planning
Fee
The applicant is required to submit the Region's Consent Application Fee of $350.00
per new lot prior to final approval of the consent.
1888113 1 of
Water Services
The applicant is advised that the subject property is located in Kitchener Zone 4 with a
static hydraulic grade line of 384 mASL. Any development with a finished road elevation
below 327.8 mASL will require individual pressure reducing devices on each water
service in accordance with Section B.2.4.7 of the Design Guidelines and Supplemental
Specifications for Municipal Services for January 2018.
Corridor Planning
Noise
The severed and retained residential lots will be impacted from road noise from traffic
on Conestoga Parkway (Highway 7/8).
The applicant is required to enter into a registered agreement with the City of Kitchener
to include the following noise attenuation measures and noise warning clauses in all
offers of purchase/sale or rental agreements for the residential units on the severed and
retained lots:
For the severed lands:
a) The unit will be fitted with forced air -ducted heating system suitably sized and
designed with provision for the installation of air conditioning in future, at the
occupant's discretion.
b) The following noise warning clause will be included in all offers of purchase and
sale and/or any rental agreements:
"The purchasers / tenants are advised that sound levels due to increasing road
traffic Highway 7/8 may occasionally interfere with some activities of the dwelling
occupants as the sound levels may exceed the sound level limits of the Region of
Waterloo and the Ministry of the Environment and Climate Change (MOECC).
This dwelling has been fitted with a forced air -ducted heating system and has
been designed with the provision of adding central air conditioning at the
occupant's discretion. Installation of central air conditioning by the occupant in
low and medium density developments will allow windows and exterior doors to
remain closed, thereby ensuring that the indoor sound levels are within the sound
level limits of the Region of Waterloo and the Environment and Climate Change
(MOECC)".
For the retained lands:
c) The following noise warning clause will be included in all offers of purchase and
sale and/or any rental agreements:
1888113
2 of 4
"The purchasers / tenants are advised that sound levels due to increasing road
traffic Highway 7/8 may occasionally interfere with some activities of the dwelling
occupants as the sound levels may exceed the sound level limits of the Region of
Waterloo and the Ministry of the Environment and Climate Change (MOECC).
Regional staff has no objection to the application subject to the following
conditions of approval for the consent:
1) That prior to final approval, the applicant submit payment to the Region of
Waterloo, the Consent Application Review Fee of $350.00.
2) That prior to final approval, the applicant enter into a Registered Development
Agreement with the City of Kitchener to secure the following noise attenuation
measures and noise warning clauses in all offers of purchase/sale or rental
agreements for the residential units on the severed and retained lots:
For the severed lands:
The unit will be fitted with forced air -ducted heating system suitably sized and
designed with provision for the installation of air conditioning in future, at the
occupant's discretion.
Purchasers / tenants are advised that sound levels due to increasing road traffic
Highway 7/8 may occasionally interfere with some activities of the dwelling
occupants as the sound levels may exceed the sound level limits of the Region of
Waterloo and the Ministry of the Environment and Climate Change (MOECC).
This dwelling has been fitted with a forced air -ducted heating system and has
been designed with the provision of adding central air conditioning at the
occupant's discretion. Installation of central air conditioning by the occupant in
low and medium density developments will allow windows and exterior doors to
remain closed, thereby ensuring that the indoor sound levels are within the sound
level limits of the Region of Waterloo and the Environment and Climate Change
(MOECC)".
For the retained lands:
"Purchasers / tenants are advised that sound levels due to increasing road traffic
Highway 7/8 may occasionally interfere with some activities of the dwelling
occupants as the sound levels may exceed the sound level limits of the Region of
Waterloo and the Ministry of the Environment and Climate Change (MOECC).
1888113
3 of 4
B 2018-003
268 Woolwich Street
Brian Holtze and Tanya Yantz
The purpose of the application to grant an easement for stormwater overflow.
Regional staff have no objection to the application.
B 2018-004
6 Pequegnat Avenue
CPM Construction Management Inc.
The purpose of the application is to create a new lot for residential development.
Community Planning
Fee
The applicant is required to submit the Region's Consent Application Fee of $350.00
per new lot prior to final approval of the consent.
Regional staff has no objection to the application subject to the following
conditions of approval for the consent:
1) That prior to final approval, the applicant submit payment to the Region of
Waterloo, the Consent Application Review Fee of $350.00.
General Comments
Any future development on the lands subject to the above -noted consent application(s)
will be subject to the provisions of Regional Development Charge By-law 14-046 or any
successor thereof.
Please accept this letter as our request for a copy of the staff reports, decisions and
minutes pertaining to each of the consent applications noted above.
Should you require Regional Staff to be in attendance at the meeting or have any
questions, please do not hesitate to contact the undersigned.
Yours truly,
L OvVv�r
Carolyn Crozier M.Sc.PI, MCIP, RPP
Principal Planner
1888113
4 of 4
Grand River Conservation Authority 400 Clyde Road, P.O. Box 729
Resource Management Division Cambridge, Ontario N1 R 5W6
Beth Brown, Supervisor of Resource Phone: (519) 621-2761 ext. 2307
Planning E-mail: bbrown@grandriver.ca
PLAN REVIEW REPORT: City of Kitchener
Holly Dyson
DATE: December 19, 2017 YOUR FILE: See below
GRCA FILE: N/A
RE: Applications for Fence:
FN 2018-001 197 Simeon Street
Applications for Signs:
SG 2018-001 431 Highland Drive West
Applications for Minor Variance:
A 2018-001 3310 King Street E
A 2018-002 375 Luella Street
A 2018-003 197 Simeon Street
Applications for Consent:
B 2018-001
301 Westmount Road
B 2018-002
67 Second Avenue
B 2018-003
268 Woolwich Street
B 2018-004
6 Pequegnat Avenue
GRCA COMMENT*:
The above noted applications are located outside the Grand River Conservation
Authority areas of interest. As such, we will not undertake a review of the applications
and plan review fees will not be required. If you have any questions, or require
additional information, please contact me.
Sincerely,
Beth Brown
Supervisor of Resource Planning
Grand River Conservation Authority
BB/dp
*These comments are respectfully submitted as advice and reflect resource concerns within the scope and mandate of the Page 1 of 1
Grand River Conservation Authority.
Holly Dyson
From: Mustafa, Shevan <SMustafa@kwhydro.ca>
Sent: 21 December, 2017 4:21 PM
To: Holly Dyson
Subject: Committee of Adjustment
Hello Holly,
"The Applicant/Authorized Agent should be aware that KWHI has overhead distribution lines below applications
to ensure compliance with all applicable standards and regulations, a minimum horizontal distance (setback) of
4.5m is required from the projection of the outermost powerline or 5.5m from the centre line of each pole".
• SG 2018-001
• B 2018-001
• B 2018-002
• B 2018-003
• B 2018-004
Note
The values takes into consideration:
• The maximum distance a KWHI typical powerline may swing (1.5m) during windy condition.
• 3.Om minimum working distance per OSHA
• Framing on 7'-6" cross -arm. Outer wire is attached approximately 3'-6" (-1 m) from centre of pole.
• If pole line is framed using 9'-6" cross -arm, the distance from centre of pole should be adjusted
accordingly. That is, 6.Om from centre line of pole.
Regards,
Shevan Mustafa
Shevan Mustafa, P.Eng
Distribution Engineer
Kitchener -Wilmot Hydro Inc.
301 Victoria St. South
Kitchener, ON N2G 4L2
Phone: (519) 745-4771 EXT. 6399
Fax: (519) 745-0643
Email: smustafa@kwhydro.ca
This email has been scanned
CONFIDENTIALITY NOTICE: This message is intended solely for the use of the individual or entity to whom
it is addressed, and may contain privileged or confidential information. If you are not the intended recipient or
the person responsible for delivering the material to the intended recipient, you are hereby notified that any
dissemination, disclosure, copying or distribution of this communication is strictly prohibited. If you received
this communication in error, please notify me immediately by return e-mail and delete this material from your
system.