HomeMy WebLinkAboutCSD-18-052 - SG 2018-004 - 8 Bridge St E
March 06, 2018
Holly Dyson
City of Kitchener
200 King Street West File: D20-20/
P.O. Box 1118 VAR KIT GEN
Kitchener, ON N2G 4G7 (3)/58 KIT, Bromberg, Garry, 1415 Huron Road
(5, 6)/53 Fairway, Fusion Homes
(7, 8) /VAR KIT, Freure North Subdivision
(10)/VAR KIT, Emmanuel Bible College
70-136 Fergus Avenue
Dear Ms. Dyson:
Re: Committee of Adjustment Meeting on March 12, 2018, City of Kitchener.
Regional staff have reviewed the following Committee of Adjustment application(s) and
have the following comments:
1. 8 Bridge Street East (SG 2018-004): No concerns to the application. However,
the owner should be made aware that any redevelopment application for these
lands may require dedicated road widening up to 13.107 metres from Bridge
Street centreline. Therefore, it is strongly recommended that the sign be located
accordingly. Otherwise, an encroachment agreement with the Region; or actual
relocation of the sign would be required at the , at such times in
future.
2. 54 Queen Street North (SG 2018-005): No concerns. The sign is on private
property and should comply with City of Kitchener Sign By-law.
3. 205 West Oak Trail (A 2018-022): No concerns.
4. 51 Simeon Street (A 2018-023): No concerns.
5. 2 Crossbridge Avenue (A 2018-024): No concerns.
6. 500 Rivertrail Avenue (A 2018-025): No concerns.
7. 70 Castlebay Street (A 2018-026): No concerns.
8. 150 Rockcliffe Drive (A 2018-027: No concerns.
9. 66 West Avenue (A 2018-028): No concerns.
10. 110, 130 and 136 Fergus Avenue (A 2018-029): No concerns.
11. 356-420 King Street West (A 2018-032): No concerns.
DOCS: 2670864
Please be advised that any development on the subject lands is subject to the
provisions of the Regional Development Charge By-law 14-046 or any successor
thereof and may require payment of Regional Development Charges for these
development(s) prior to the issuance of a building permit.
The comments contained in this letter pertain to the Application number(s) listed. If a
site is subject to more than one application, additional comments may apply.
Please forward any decisions on the above mentioned Application number(s) to the
undersigned.
Yours Truly,
Joginder Bhatia
Transportation Planner
(519) 575-4757 ext 3867
Holly Dyson
From:Mustafa, Shevan <SMustafa@kwhydro.ca>
Sent:02 March, 2018 8:43 AM
To:Holly Dyson
Subject:Committee of Adjustments
Hello Holly,
“The Applicant/Authorized Agent should be aware that KWHI has overhead distribution lines below applications
to ensure compliance with all applicable standards and regulations, a minimum horizontal distance (setback) of
4.5m is required from the projection of the outermost powerline or 5.5m from the centre line of each pole”.
SG 2018-004
B 2018-016
B 2018-017 to B 2018-19
B 2018-021
B 2018-022
B 2018-023
Note
The values takes into consideration:
The maximum distance a KWHI typical powerline may swing (1.5m) during windy condition.
3.0m minimum working distance per OHSA
Framing on 7’-6” cross-arm. Outer wire is attached approximately 3’-6” (~1m) from centre of pole.
If pole line is framed using 9’-6” cross-arm, the distance from centre of pole should be adjusted
accordingly. That is, 6.0m from centre line of pole.
Regards,
{ŷĻǝğƓaǒƭƷğŅğͲ t͵9Ɠŭ
5źƭƷƩźĬǒƷźƚƓ9ƓŭźƓĻĻƩ
YźƷĭŷĻƓĻƩźƌƒƚƷIǤķƩƚLƓĭ͵
ЌЉЊźĭƷƚƩźğ{Ʒ͵{ƚǒƷŷ
YźƷĭŷĻƓĻƩͲhbbЋDЍ\[Ћ
tŷƚƓĻʹΛЎЊВΜАЍЎЍААЊ9͵ЏЌВВ
CğǣʹΛЎЊВΜАЍЎЉЏЍЌ
9ƒğźƌʹƭƒǒƭƷğŅğθƉǞŷǤķƩƚ͵ĭğ
This email has been scanned
CONFIDENTIALITY NOTICE: This message is intended solely for the use of the individual or entity to whom
it is addressed, and may contain privileged or confidential information. If you are not the intended recipient or
the person responsible for delivering the material to the intended recipient, you are hereby notified that any
dissemination, disclosure, copying or distribution of this communication is strictly prohibited. If you received
this communication in error, please notify me immediately by return e-mail and delete this material from your
system.
1