Loading...
HomeMy WebLinkAboutCSD-18-083 - B 2018-026 and B 2018-027 - 114-120 Victoria Street SouthJ Staff Report Community Services Department www.kitchenerca REPORT TO: Committee of Adjustment DATE OF MEETING: April 17, 2018 SUBMITTED BY: Juliane von Westerholt, Senior Planner — 519-741-2200 ext. 7157 PREPARED BY: Juliane von Westerholt, Senior Planner — 519-741-2200 ext. 7157 WARD: 9 DATE OF REPORT: April 6, 2018 REPORT #: CSD -18-083 SUBJECT: Application B2018-026, and B2018-027 114-120 Victoria Street South Applicant — GSP Group Approve with Conditions Location Map: 1"14-1 LU victoria Jtreet soutn *** This information is available in accessible formats upon request. *** Please call 519-741-2345 or TTY 1-866-969-9994 for assistance. RECOMMENDATIONS That application B2018-0026, requesting permission to sever a parcel of land from 114-120 Victoria Street that has a width of 40.8 metres, a depth of 65.6 metres, and an area of 2673.6 square metres and to retain a parcel having a lot width of 64.9 metres with a depth of 65.6 metres and an area of 3878 metres squared and to establish reciprocal shrinking blanket easements for the purpose of rights of access for both pedestrians and vehicles as well as parking be approved, subject to the following conditions: 1. That the Owner provide a digital file of the deposited reference plan(s) prepared by an Ontario Land Surveyor in .dwg (AutoCad) or .dgn (Microstation) format, as well as one full size paper copy of the plan(s). The digital file needs to be submitted according to the City of Kitchener's Digital Submission Standards to the satisfaction of the City's Mapping Technologist. 2. That the Owner shall obtain a tax certificate from the City of Kitchener to verify that there are no outstanding taxes on the subject property to the satisfaction of the City's Revenue Division. 3. That the owner make financial arrangements to the satisfaction of the City's Engineering Services, for the installation of all new service connections to the severed lands and/or retained lands. 4. That the owner make financial arrangements for the installation, to City standards, of boulevard landscaping including street trees, and a paved driveway ramp, on the severed lands and/or retained lands to the satisfaction of the City's Engineering Services. 5. That a servicing plan showing outlets to the municipal servicing system be provided for both the severed and retained lands to the satisfaction of Engineering Services . 6. That the Zoning By-law 2018-036 be in full force and effect or that an appropriate minor variance application be submitted and approved with respect to any matters of zoning compliance to the satisfaction of the Director of Planning. 7. That the Transfer Easement document(s) required to create the Easement(s) being approved herein shall include the following and shall be approved by the City Solicitor (optional: in consultation with the City's Director of Planning): a. a clear and specific description of the purpose of the Easement(s) and of the rights and privileges being granted therein (including detailed terms and/or conditions of any required maintenance, liability and/or cost sharing provisions related thereto); b. a clause/statement/wording confirming that the Easement(s) being granted shall be maintained and registered on title in perpetuity and shall not be amended, released or otherwise dealt with without the express written consent of the City. 8. That a satisfactory Solicitor's Undertaking to register the approved Transfer Easement(s) and to immediately thereafter provide copies thereof to the City Solicitor be provided to the City Solicitor. 9. That the Owner submit a complete Development and Reconstruction As - Recorded Tracking Form (as per the Public Sector Accounting Board (PSAB) S. 3150) together with a digital submission of all AutoCAD drawings required for the site (Grading, Servicing etc.) with the corresponding correct layer names and numbering system to the satisfaction of the Director of Engineering Services for the severed and retained lands. 10. That the owner make financial arrangements to the satisfaction of the City's Engineering Services for the installation, to City standards, of boulevard landscaping including street trees, and a paved driveway ramp, on the severed lands, or otherwise receive relief from Engineering Services for this requirement. 11. That the Owner provides Engineering staff with confirmation that the basement elevation of the building can be drained by gravity to the street sewers, to the satisfaction of the Director of Engineering Services. Where this cannot be achieved, the owner is required to pump the sewage via a pump and forcemain to the property line and have a gravity sewer from the property line to the street, at the cost of the Owner. 12.That prior to final approval, the Region shall approve the environmental noise study entitled "Noise Feasibility Study, Proposed Mixed -Use Development, 114-120 Victoria Street South, Kitchener, ON" dated October 25, 2017 as prepared by HGC Engineering, and, if necessary, based on the findings of the report, the applicant shall enter into a Registered Development Agreement with the Region of Waterloo and/or the City of Kitchener, to implement the recommendations of the report. 13. That the Owner submit and receive approval of all building permits including any required demolition permits for any buildings currently on site as well as permits for new construction. II. That Application B2018-027 proposing to create a blanket easement over the retained lands in favour of the severed lands for the purpose of storm water management to be approved, subject to the following conditions: 1. That Application B2018-026 receives full and final approval. 2. That the Owner provide a digital file of the deposited reference plan(s) prepared by an Ontario Land Surveyor in .dwg (AutoCad) or .dgn (Microstation) format, as well as one full size paper copy of the plan(s). The digital file needs to be submitted according to the City of Kitchener's Digital Submission Standards to the satisfaction of the City's Mapping Technologist. 3. That the Owner shall obtain a tax certificate from the City of Kitchener to verify that there are no outstanding taxes on the subject property to the satisfaction of the City's Revenue Division. 4. That the Transfer Easement document(s) required to create the Easement(s) being approved herein shall include the following and shall be approved by the City Solicitor (optional: in consultation with the City's Director of Planning): a. a clear and specific description of the purpose of the Easement(s) and of the rights and privileges being granted therein (including detailed terms and/or conditions of any required maintenance, liability and/or cost sharing provisions related thereto); b. a clause/statement/wording confirming that the Easement(s) being granted shall be maintained and registered on title in perpetuity and shall not be amended, released or otherwise dealt with without the express written consent of the City. 5. That a satisfactory Solicitor's Undertaking to register the approved Transfer Easement(s) and to immediately thereafter provide copies thereof to the City Solicitor be provided to the City Solicitor. City Planning staff conducted a site inspection of the property on April 9, 2018. Subject Property: 114-120 Victoria Street South REPORT Planning Comments: The subject property is designated `Innovation District' in the Official Plan (OP) and is located in the Central Major Transit Station Area at the future site of the Multi -modal Transit Hub. The Innovation District is characterized by many old large industrial buildings which either have been converted to loft style office, residential and other viable uses or have the potential to do so. This area of the city is expected to evolve and transform into a dense urban contemporary setting with continued growth in the high tech industry coupled with the research office uses affiliated with the nearby post- secondary institutions. The City's Official plan policy framework found in Policies 15.D.2.50 to 15.D.2.52 encourage growth in this area to occur by permitting a full range of complimentary commercial uses and encouraging high density residential uses. Through Policy 15.D.2.54 the City also recognizes the importance of conserving cultural heritage resources within the former warehouse district, now the Innovation District. The applicant has proposed the creation of a lot and the creation of blanket easements over the severed and retained lots for access and for sanitary servicing. The lands will be developed with a 6 storey office building and an addition to the existing building, which is a cultural heritage resource (former Huck Glove Building) that is being conserved through this process. The retained property will be developed with a 26 storey mixed use tower which includes residential and at grade commercial uses. The lands have recently gone through a rezoning process and a site specific zoning by- law has been passed by Council on March 19, 2018 to allow an increase in FSR from 3.0 to 7.0 through the use of Bonusing and a Section 37 Agreement, a parking reduction from 411 to 233 spaces for the entire site to be shared between all the uses and to be unbundled from the residential units, to recognize multiple setbacks that would permit the development as shown on the site plan attached to this application and finally to require a holding provision that is to be lifted by by-law once a record of site condition is completed for the subject lands and has received the MOECC approval. The last day to appeal this by-law is on April 17, 2018, which coincides with the Committee of Adjustment date. Since the by-law will not be in full force and effect by the date of the Committee of Adjustment meeting scheduled to deal with the consents subject to this application, staff will be requesting a condition of approval that the Zoning By-law 2018- 034 be in full force and effect or that an appropriate application for a minor variance be submitted to ensure zoning compliance for the creation of the lots. With respect to the criteria for the subdivision of land listed in Section 51(24) of the Planning Act, R.S.O. 1990, c. P. 13, Planning staff is of the opinion that the proposed severances conform to the City's Official Plan and will allow for orderly development that is compatible with the existing community. The severed and retained lots will both comply with the regulations of the Warehouse District Six (D-6) zone once by-law 2018- 034 is in effect. The dimensions and shapes of the proposed lots are appropriate and suitable for the proposed use of the lands, the lands front on an established public street, and both parcels of land can be serviced with independent and adequate service connections to municipal services. Staff is further of the opinion that the proposal is consistent with the Provincial Policy Statement and conforms to the Growth Plan for the Greater Golden Horseshoe. Based on the foregoing, Planning staff recommends that Consent Applications B2018- 026 and , B2018-027, requesting permission to sever a parcel of land from 114-120 Victoria Street that has a width of 40.8 metres, a depth of 65.6 metres, and an area of 2673.6 square metres and to retain a parcel having a lot width of 64.9 metres with a depth of 65.6 metres and an area of 3878 metres squared and to establish reciprocal shrinking blanket easements for the purpose of rights of access for both pedestrians and vehicles as well as parking for both the severed and retained parcels; and a second blanket easement over the retained lands in favour of the severed lands for the purpose of the provision of storm water management be approved subject to the conditions outlined in the Recommendations section of this report. View of 114-120 Victoria Street South looking south. Building Comments: The Building Division has no objections to the proposed consent. Region of Waterloo and Area Municipalities' Design Guidelines and Supplemental Specifications for Municipal Services (DGSSMS) allows only one service per lot. Should a severance be approved, additional services will be required for severed lot — a building permit will be required for this work. Separate building permit(s) will also be required for the demolition of all existing buildings, as well as construction of all new buildings. Transportation Comments: Transportation Services have no concerns with the proposed application. Please note that the required sidewalks are already negotiated in the Site Plan process. Engineering Comments: Severance of any blocks within the subject lands will require separate, individual service connections for sanitary, storm, and water, in accordance with City policies. The sump pump should be connected to a service lateral going to the municipal storm sewer. The owner is required to make satisfactory financial arrangements with the Engineering Division for the installation of new services that may be required to service this property, all prior to severance approval. Our records indicate municipal water, storm and sanitary services are currently available to service this property. Each severed lot will require a sanitary, a storm and a water service. Any further enquiries in this regard should be directed to Natasha Prepas-Strobeck (519-741-2200 ext. 7136). Any new driveways are to be built to City of Kitchener standards. All work is at the owner's expense and all work needs to be completed prior to occupancy of the building. A servicing plan showing outlets to the municipal servicing system and proposed easements will be required to the satisfaction of the Engineering Division prior to severance approval. As per the Public Sector Accounting Board (PSAB) S. 3150 the Development and Reconstruction As -Recorded Tracking Form is required to be filled out and submitted along with a digital submission of all AutoCAD drawings required for the site (Grading, Servicing etc.) with the corresponding correct layer names and numbering system to the satisfaction of the Engineering Division prior to severance approval. The owner must ensure that the basement elevation of the building can be drained by gravity to the street sewers. If this is not the case, then the owner would have to pump the sewage via a pump and forcemain to the property line and have a gravity sewer from the property line to the street. Region of Waterloo Comments: The Region has no objection provided the following condition be included: That prior to final approval, the applicant provide an update to the environmental noise study entitled "Noise Feasibility Study, Proposed Mixed -Use Development, 114-120 Victoria Street South, Kitchener, ON" dated October 25, 2017 as prepared by HGC Engineering, and, if necessary, based on the findings of the report, enter into a Registered Development Agreement with the Region of Waterloo and/or the City of Kitchener, to implement the recommendations of the report. Juliane von Westerholt, MCIP, RPP Senior Planner Region of Waterloo File No. D20-20/18 KIT April 6, 2018 Holly Dyson Committee of Adjustment City of Kitchener P.O. Box 1118 200 King Street East Kitchener, ON N2G 4G7 PLANNING, DEVELOPMENT AND LEGISLATIVE SERVICES Community Planning 150 Frederick Street 8th Floor Kitchener Ontario N2G 4J3 Canada Telephone: 519-575-4400 TTY: 519-575-4608 Fax: 519-575-4466 www. reg ionofwate rl oo.ca Carolyn Crozier 575-4757 ext. 3657 Re: Comments for Consent Applications B2018-026 and B2018-027 Committee of Adjustment Hearing April 17, 2018 CITY OF KITCHENER B 2018-026 and B2018-027 114-120 Victoria Street South 114-120 Victoria Street South Inc. The purpose of the application is to sever the site into two lots and to establish reciprocal shrinking blanket easements for rights of access and stormwater management. Community Planning Fee The Region acknowledges receipt of the required Consent Application Fee of $350.00. Corridor Planning Noise The applicant has submitted an environmental noise study entitled "Noise Feasibility Study, Proposed Mixed -Use Development, 114-120 Victoria Street South, Kitchener, ON" dated October 25, 2017 as prepared by HGC Engineering. Document Number: 2695988 Region staff have identified several items that need clarification on the study as it pertains to stationary noise and have brought these items to the attention of the noise consultant. As such, an update to the report will be required. If necessary, based on the findings of the report, the applicant will be required to enter into a Registered Development Agreement with the Region of Waterloo and/or the City of Kitchener to implement the recommendations of the report. Regional staff has no objection to the application subject to the following condition of approval for the consent: 1) That prior to final approval, the applicant provide an update to the environmental noise study entitled "Noise Feasibility Study, Proposed Mixed -Use Development, 114-120 Victoria Street South, Kitchener, ON" dated October 25, 2017 as prepared by HGC Engineering, and, if necessary, based on the findings of the report, enter into a Registered Development Agreement with the Region of Waterloo and/or the City of Kitchener, to implement the recommendations of the report. General Comments Any future development on the lands subject to the above -noted consent application(s) will be subject to the provisions of Regional Development Charge By-law 14-046 or any successor thereof. Please accept this letter as our request for a copy of the staff reports, decisions and minutes pertaining to each of the consent applications noted above. Should you require Regional Staff to be in attendance at the meeting or have any questions, please do not hesitate to contact the undersigned. Yours truly, n � Carolyn Crozier M.Sc.PI, MCIP, RPP Principal Planner Document Number: 2695988 400 Clyde Road, P.O. Box 729 Grand River Conservation Authority Cambridge, Ontario N 1 R 5W6 Resource Management Division Phone: (519) 621-2761 ext. 2319 Trisha Hughes, Resource Planner Fax: (519) 621-4945 E-mail: thug hes@grandriver.ca PLAN REVIEW REPORT: City of Kitchener Holly Dyson DATE: YOUR FILE: GRCA FILE: April 5, 2018 B2018-026 to 027 — 114-120 B2018-026-027 — 114-120 Victoria Street South Victoria St S RE: Application for Consent B2018-026 to B2018-027 114-120 Victoria Street South, City of Kitchener 114-120 Victoria Street South Inc. GRCA COMMENT*: The Grand River Conservation Authority (GRCA) has no objection to the above noted consent application. BACKGROUND: 1. Resource Issues: Information currently available at our office indicates that a small portion of the subject property is within the flood fringe portion of the floodplain associated with Schneider Creek, as well as the 5 metre regulatory allowance to the floodplain. 2. Legislative/Policy Requirements and Implications: It is our understanding that the applicant is proposing to sever the subject property into two lots. We have no objection to the severance based on the sketch prepared by ACI Survey Consultants (revised January 9, 2018), as there is sufficient area on both the retained and severed lots for future development outside the regulated area. Please note that any future development proposed within GRCA regulated areas will require prior written approval from the GRCA in the form of a permit pursuant to Ontario Regulation 150/06. 3. Plan Review Fees: The GRCA applies Plan Review Fees for Planning Act applications located within GRCA areas of interest. This application is considered a 'minor' consent application. Where multiple applications are submitted for the same property, the highest fee is applied. Recently we have also commented on a minor variance application, zone change application and site plan application where we received a fee of $390. Therefore, we will not charge for our review of this consent application. Page 1 of 2 * These comments are respectfully submitted as advice and reflect resource concerns within the scope and mandate of the Grand River Conservation Authority We trust this information is of assistance. If you have any questions, or require additional information, please contact the undersigned. Sincerely, //,v/ hW risha Hughes Resource Planner Grand River Conservation Authority cc: 114-120 Victoria Street South Inc., 697 King Street West, Suite 205A, Kitchener, ON N2G 1C7 GSP Group Inc., 72 Victoria Street South, Suite 201, Kitchener, ON N2G 4Y9 Page 2 of 2 ' These comments are respectfully submitted as advice and reflect resource concerns within the scope and mandate of the Grand River Conservation Authority