Loading...
HomeMy WebLinkAboutDSD-19-171 - B 2019-029 & A 2019-063 - 4278 King St EStaff Report Development Services Department 1 K�-R www.ki tch en er. c a REPORT TO: Committee of Adjustment DATE OF MEETING: July 16, 2019 SUBMITTED BY: Juliane von Westerholt, Senior Planner - 519-741-2200 ext. 7157 PREPARED BY: Andrew Pinnell, Planner — 519-741-2200 ex. 7668 WARD: 3 DATE OF REPORT: July 5, 2019 REPORT #: DSD -19-171 SUBJECT: B2019-029 and A2019-063 — 4278 King Street East Owners — Sportsworld Crossing Inc. Approve subject to conditions REPORT Planning Comments: The subject property is located at the corner of King Street East and Sportsworld Crossing Road (private street), and is included within the Sportsworld Crossing development, in the Pioneer Tower East Planning Community. The subject property is owned by Sportsworld Crossing Inc. and contains an existing one - storey, 1,745 square metre office building that was constructed in approximately 2004 (occupied by Christian Horizons), as well as a small hydro building. The property is designated Commercial Campus in the Official Plan and is classified as a Major Transit Station Area within the Urban Structure. The property is zoned Commercial Campus Zone (C-8) with *** This information is available in accessible formats upon request. *** Please call 519-741-2345 or TTY 1-866-969-9994 for assistance. Special Regulation Provision 449R in the Zoning By-law. Recently, City Council approved new zoning for the property [i.e., COM -4 (37)], but this has been appealed to the Local Planning Appeal Tribunal by third parties and is not force at this time. On May 31, 2019, Planning staff conducted a site inspection of the subject property. In order to facilitate the creation of a lot to contain the existing office building, and facilitate future development on the retained lands, the applicant is requesting: Approval of Consent Application B2019-029 to: a. Create a new, "flag lot" (i.e., Lands to be Severed/ Parcel A on the plan submitted with the application form) with 14.0 metres of frontage on King Street East, a depth of approximately 178 metres, and an area of 0.84 hectares. Parcel A would be irregularly shaped and would contain the existing office building, associated parking, large retaining wall, and hydro building, as well as a proposed shared driveway access for Parcel A and Parcel B (note the existing driveway access is proposed to be modified). The retained lot (i.e., Lands to be Retained / Parcel 8 on the plan submitted with the application form) would have 95.4 metres of frontage on King Street East, a depth of approximately 140 metres, and an area of 1.15 hectares. Parcel B would be irregularly shaped and would abut Sportsworld Crossing Drive at the southeast end. The retained lot is vacant and would be for future development. Access would be provided via a shared driveway, secured through an easement over Parcel A (described immediately below). b. Create an easement over Parcel A in favour of Parcel B for a shared driveway access. The easement would have a width of 14.0 metres and an approximate depth of 69.6 metres. 2. Approval of Minor Variance Application A2019-063 for Parcel A, which requests a: a. Lot width of 14.0 metres, whereas Section 13A.2.1 of Zoning By-law 85-1 requires a minimum lot width of 25.0 metres (note that the COM -4 Zone, in Section 9.3 of By-law 2019-051, requires a minimum lot width of 30.0 metres), and b. Side yard of 1.2 metres for the existing hydro building, whereas Section 13A.2.1 of Zoning By- law 85-1 requires a minimum side yard of 3.0 metres (note that the COM -4 Zone, in Section 9.3 of By-law 2019-051, also requires a minimum side yard of 3.0 metres). The applicant has advised that all municipal services to the existing office building on proposed Parcel A are located within Parcel A. Also, the applicant has advised that the existing stormwater management scheme for Parcel A provides for stormwater control through the existing storm sewer network and that no overland flow is directed towards Parcel B. However, it should be noted that there is a Kitchener - Wilmot Hydro ductbank that services Parcel A and extends from King Street, over Parcel B, to the small, existing hydro building on Parcel A (see Appendix D). Although flag lots are sometimes undesirable for a number of reasons, in this case, Planning staff does not have concerns with the proposal. Planning staff offers the following comments based on considerations included within a best practices document prepared by staff to assist in the review of applications proposing flag lots: Emergency Access: Fire Services has not identified any emergency services concerns, except for addressing. However, the addressing concern can be resolved via a future site plan application (recommended as a condition of consent approval). Transportation: o The proposal facilitates the creation of a shared driveway between two development sites, both with frontage on a Regional Road. Sharing the driveway is desirable because it reduces potential for vehicular and pedestrian conflicts where the driveway connects to the street. o Transportation Services has stated that it has no concerns with the proposed application. Planning: o The existing building at the rear (furthest from the street) of Parcel A is already constructed. The subject Consent Application will facilitate the development of the lands in front, closest to the street (typically, the opposite is true, which is sometimes a concern). This is positive because it facilitates an opportunity for street -oriented and transit -oriented development within a Major Transit Station Area. o Although privacy is often a concern with flag lots, the existing development maintains minimum setbacks and is not located in a residential context. Planning staff does not have concerns with respect to privacy. o Planning staff also notes that Parcel A is already distinct from Parcel B due to a grade differential: Parcel A sits at a high grade/elevation, while Parcel B sits at a low grade/elevation (similar grade as King Street). Crime Prevention Through Environmental Design (CPTED): Planning staff does not have concerns because the existing building at the rear of Parcel A is already constructed, is highly visible from bounding streets because of its high grade/elevation, and will be accessible via a new driveway. With respect to the criteria for the subdivision of land listed in Section 51 (24) of the Planning Act, R.S.O. 1990, c.P.13, Planning staff offers the following comments. The uses of the resultant parcels conform to the City's Official Plan. Policy 17.E.20.5. states: Applications for consent to create new lots will only be granted where: a) the lots comply with the policies of this Plan, any Community Plan and/or Secondary Plan, and that the lots are in conformity with the Zoning By-law, or a minor variance has been granted to correct any deficiencies; b) the lots reflect the general scale and character of the established development pattern of surrounding lands by taking into consideration lot frontages, areas, and configurations; Planning staff is of the opinion that the requested variance for lot width is appropriate (see below analysis) and that, in this specific case, the resultant lots reflect the general scale and character of the established development pattern of surrounding lands, and that future development is not compromised. The dimensions and shapes of the resultant parcels are appropriate. The lands are suitable for the purposes for which they are to be severed. In addition, the resultant lots will be subject to site plan control which will ensure orderly development. Lastly, the resultant parcels will be serviced with independent, adequate municipal service connections. In considering the four tests for minor variances as outlined in Section 45(1) of the Planning Act, R.S.O., 1990 Chap. P. 13, as amended, Planning staff offer the following comments. The requested variances for minimum lot width and minimum side yard maintain the general intent of the Official Plan and Zoning By-law for the following reasons. The requested 14.0 metre lot width is sufficient to allow all necessary site development components, including the driveway, sidewalk, lighting, landscaping, and municipal services, etc. Moreover, Planning staff recommends an approval condition to require the registration of a new site plan agreement over Parcel A to address all site development matters. The requested 1.2 metre side yard setback applies only to the hydro building and maintains an adequate buffer to the Parcel B. Kitchener -Wilmot Hydro has advised that the requested setback is adequate. The requested variances are minor since they will not cause unacceptably adverse impacts to adjacent properties. The lot width is sufficient to provide a shared driveway and associated infrastructure, while the potentially reducing pedestrian and vehicular conflicts. Also, appropriate side yard buffers are maintained from the hydro building to the side lot line. The requested variances are desirable for the appropriate development (Parcel B) / use (Parcel A) of the land. The variances will facilitate the creation of Parcel A and the continued use of the existing office use, which is permitted by the C-8 and COM -4 zoning. The retained parcel does not require variances, but its creation and future development would be facilitated by the creation of Parcel A (which is dependent upon the variances). Based on the foregoing, Planning staff recommends that the Consent Application and Minor Variance Application be approved, subject to the conditions outlined in the Recommendation section of this report. Heritage Planning Comments: No heritage planning concerns. Environmental Planning Comments: Tree Management Policy requirements will be addressed through the site plan process at a later date. Building Comments: The Building Division has no objections to the proposed consent. Region of Waterloo and Area Municipalities' Design Guidelines and Supplemental Specifications for Municipal Services (DGSSMS) allows only one service per lot. Separate building permit(s) will be required for the construction of any new commercial buildings. Fire Services Comments: The most significant issue is the addressing of existing building. It is required that the address for the existing building be visible from the street. As part of the condition for site plan approval, the owner/applicant should be required to obtain approval of and erect a sign near the driveway entrance that clearly indicating that the driveway is for 4278 King St. E. Additional addressing signage for the development of the retained lot would be required at the time of future development. Fire route plans would be required for both properties. Fire Services notes that there is a private hydrant for the existing building. Transportation Services Comments: Transportation Services has no concerns with the proposed application. Operations Comments: Parkland dedication is not required for this application as parkland dedication was taken via SP07/056/S/JVW in 2008. A deferral agreement was also entered into for MTO in which the deferred amount was paid in 2011. Engineering Comments: Severance of any blocks within the subject lands will require separate, individual service connections for sanitary, storm, and water, in accordance with City policies. The servicing plan submitted with the application indicate each property already has services. Please provide confirmation that no stormwater is required to flow overland from the severed portion over the retained portion. Any new driveways are to be built and existing driveways to be removed to Region of Waterloo standards. All work is at the owner's expense. The severed portion will be required to submit a Stamp Plan `A' application and fulfill all conditions prior to severance approval. Additional Engineering comments for the severed lands will be provided through that circulation. Kitchener -Wilmot Hydro Comments: A servicing easement will be required in order to protect the existing service to #4278 (i.e., the Christian Horizons building) through the retained lot (Parcel B). The easement must be a minimum 2.Om in width and run over the entire length of the existing ductbank from the property line to the transformer enclosure building (see Appendix D). [Planning staff note: this easement will be required as a condition of consent approval]. This easement will eliminate the possibility of buildings being constructed over top of the existing duct structure. Alternatively, the owner/applicant may relocate the existing ductbank (this option would be far more costly than the easement option). If the owner/developer would like to relocate the existing service instead of granting an easement, the owner/developer will need to contact KWHI to make arrangements for the relocation. Note that, presently, the transformer enclosure building services the severed lot only (Parcel A). The proposed lot line that separates Parcel A from Parcel B is very close to the edge of the building, but is acceptable. Any changes to the transformer enclosure building will be at the customer's expense. Note that only one service is allowed per address/lot. Multiple services are not permitted. RECOMMENDATION A. That Consent Application B2019-029 requesting consent to: a. create a new lot with approximately 14.0 metres of frontage on King Street East, a depth of approximately 178 metres, and an area of approximately 0.84 hectares, and b. create an easement over the severed parcel in favour of the retained parcel for a shared driveway access with an approximate width of a width of 14.0 metres and an approximate depth of 69.6 metres, be approved, subject to the following conditions: 1. That the Owner shall obtain a tax certificate from the City of Kitchener to verify that there are no outstanding taxes on the subject property(ies) to the satisfaction of the City's Revenue Division. 2. That the owner shall provide a digital file of the deposited reference plan(s) prepared by an Ontario Land Surveyor in PDF and either .dwg (AutoCad) or .dgn (Microstation) format, as well as two full sized paper copies of the plan(s). The digital file needs to be submitted according to the City of Kitchener's Digital Submission Standards to the satisfaction of the City's Mapping Technologist. 3. That variance application A2019-063 receive final approval. 4. That the owner shall provide confirmation that no stormwater is required to flow overland from the severed portion over the retained portion, to the satisfaction of the City's Engineering Services. 5. That the Transfer Easement documents required to create the Easement being approved herein shall include the following and shall be approved by the City Solicitor, in consultation with the City's Director of Planning: a. a clear and specific description of the purpose of the Easement and of the rights and privileges being granted therein (including detailed terms and/or conditions of any required maintenance, liability and/or cost sharing provisions related thereto); b. a clause/statement/wording confirming that the Easement being granted shall be maintained and registered on title in perpetuity and shall not be amended, released or otherwise dealt with without the express written consent of the City 6. That a satisfactory Solicitor's Undertaking to register the approved Transfer Easement and to immediately thereafter provide copies thereof to the City Solicitor be provided to the City Solicitor. 7. The owner shall submit a draft copy of the proposed Transfer for the severed parcel for review and approval, to the satisfaction of the City Solicitor. 8. The owner shall apply for, obtain approval of, and finalize a Stamp Plan "A" Site Plan Application for the severed lands, including registration on title of a new Section 41 Agreement. The Application shall, among other requirements,: a. address the following site changes, including, but not limited to, constructing a new driveway and closing the existing driveway, adding/revising address signage, relocating the sidewalk, relocating lighting, and adding landscape buffers, all within the 14m wide frontage. Note that no retaining walls will be permitted within Driveway Visibility Triangles, b. request removal of the severed lands from the existing, overall Sportsworld Crossing Section 41 Agreement, with the retained lands to remain part of said Agreement. c. propose to restore the as -built parking and loading layout to the layout approved through SP04/32/K/LT. Alternatively, the applicant may request revisions allow existing layout, and shall obtain approval, d. address any Tree Management Policy matters, e. address any zoning non-compliance matters (e.g., barrier -free parking), and f. require the owner shall obtain access permits from the Region for the new access and the closure of the existing access. 9. The owner shall convey a servicing easement over the retained lands in favour of Kitchener -Wilmot Hydro for the existing ductbank extending from King Street to the severed lands, to the satisfaction Kitchener -Wilmot Hydro, or otherwise receive a written exemption from this requirement, from Kitchener -Wilmot Hydro. B. That Minor Variance Application B2019-063 requesting relief from: a. Section 13A.2.1 of Zoning By-law 85-1 to allow a minimum lot width of 14.0 metres, whereas 25.0 metres is required, and b. Section 13A.2.1 of Zoning By-law 85-1 to allow a minimum side yard of 1.2 metres, whereas 3.0 metres is required for an existing hydro building, be approved, without conditions. C. That Minor Variance Application B2019-063 requesting relief from: a. Section 9.3 of By-law 2019-051 to allow a minimum lot width of 14.0 metres, whereas 30.0 metres is required, and b. Section 9.3 of By-law 2019-051 to allow a minimum side yard of 1.2 metres, whereas 3.0 metres is required for an existing hydro building, be approved, subject to this minor variance becoming effective only at such time as Zoning By- law 2019-051 comes into force, pursuant to section 34 (30) of the Planning Act, R. S. O. 1990, c. P 13, as amended. At such time, the variance shall be deemed to have come into force as of the date of this decision. Further, should the regulations relating to the requested variance change prior to Zoning By-law 2019-051 coming into force, this variance shall be void. Andrew Pinnell, MCIP, RPP Planner Juliane von Westerholt, MCIP, RPP Senior Planner Attachments: • Appendix A — Severance Sketch with aerial photo submitted with application form Appendix B — Severance Sketch submitted with application form Appendix C — Existing Servicing Plan submitted with application form Appendix D — Easement sketch prepared by KW Hydro (excerpt) Appendix A ly NI 71 0 77 i4 > >1 H 0 \w A E 72 6 -P4! LO L KlYowly ARC=26,2 39.6 % As PART SPOF;t -rSWCIRLD CR<) C=25,7 AR 0 '. 2. SSING R04t) 'AP rueelsras m < ;mu HN z > 0 A z 0 m CO H -n ;v, c % OOM 9 CUfT Z A 0 m -I A 3 ;u 0 Cp - 0 m > At- ml '06 m 7 > ZZ ;u m nO ART 58R-5746 121.3 70.1 —PARI` 69.6 PART 10. 5$4 18gig ly NI 71 0 77 i4 > >1 H 0 \w A E 72 6 -P4! LO L KlYowly ARC=26,2 39.6 % As PART SPOF;t -rSWCIRLD CR<) C=25,7 AR 0 '. 2. SSING R04t) 'AP rueelsras m < ;mu HN z > 0 A z 0 m CO H -n ;v, c % OOM 9 CUfT Z A 0 m -I A 3 ;u 0 Cp - 0 m > At- ml '06 m 7 > ZZ ;u m Appendix B o n �0 vi -i ni PIN 0 22732 -XO (LT) ^ G� i m Pz N C c' m4111 -RT 5F<- iY= �4Ar ` 121.3 ? 31b2/t� J4� itA8P 76.1 PART 11,51'251iP FB9.1i 1 ffAL7 f RftNEWAY A �ao�ao nsi usEnenN ...... 69.6r r 10, 0 w O o Y s =D T^ p er n r0 a � raP x n __j 'yw" a❑ c u A �h 'Con o Q h'j [nn c r ? �Y A = zN' } FA bA rmnd� 9 R =i. z y N F: 7d 5` A = "'"fid OL- Gm*� ti nmrZeOto r = 12.6 W A bN Z RI ffi n Iw SllplfC'7 m s � n N ` r..gr?7 TO 7"T Inr57xuarw7 ``*r u �N. O n �j 1• no`7 cr. KNOWN A3ARC" 26.2 30.6 :A n SF'ORTSWRLD CRe� ~ARC■25.7RnaT 3NGPIN ap-1a5!Q ROAD 207-12 SFF SNAW NQ 2 IFS lNsrRUMf Y (4TJ S1,11- M WRa191 �` 45EMfNF5 955588. 05 48276$ AND WR -31.8 co co co �d " 3 3 ��a z 74 w m > w ra � z r N C m9w-Qas p T x n na my �m Ll nmm� n a'j > 3 S O z Tz- ;n'= Ofp 5;H 'a M, zma w v�o �_y 2pp> 9p T Z e m aa O x{ mmyw Yi nmw A IT -11 4 D)S m z crm9- op 0N m vex om neon TDo m Q �i has Z o z m w S Via° Z Z SGS i 1 o n z a 3 m""� " mi w z c Z .i7 C7 m on� �o m mm c m o a Appendix C WN 51M i" % 5 / / �| _ � ' { , 9P ^ � �\�\d « ��/{){�� WN 51M i" % 5 / / �| _ � ' { , 9P Rppenaix u - � !| ' c �$ ' §`� !■| ��� k;� ■ ■|; >4 > �k B ` is §2 F) AW | �!■ I �� Region of Waterloo Holly Dyson Committee of Adjustment City of Kitchener P.O. Box 1118 200 King Street East Kitchener, ON N2G 4G7 *Z11 P111P4.1 PLANNING, DEVELOPMENT AND LEGISLATIVE SERVICES Community Planning 150 Frederick Street 8th Floor Kitchener Ontario N2G U Canada Telephone: 519-575-4400 TTY: 519-575-4608 Fax: 519-575-4466 www. reg i o nofwate rl oo. ca Matthew Colley 575-4757 ext. 3210 File No. D20-20/19 KIT July 9, 2019 Re: Comments for Consent Application B2019-025 through B2019-050 and CC2019-005 to CC2019-007 Committee of Adjustment Hearing July 16, 2019 CITY OF KITCHENER 4283 King Street East 1719288 Ontario Inc. The owner/applicant is proposing to extend an existing lease. Regional staff has no objection to the application. 4285 King Street East 1719288 Ontario Inc. The owner/applicant is proposing to extend an existing lease. Regional Staff has no objection to the application. Document Number: 3051281 Version: 1 B2019-027 1340 Fischer -Hallman Road Activa Holdings Inc. The owner/applicant is proposing a consent application to create a stormwater easement for the purpose of receiving stormwater from the adjacent lands to the north and permitting it to flow through to the outlet (Strasburg Creek). Regional Staff has no objection to the application. B2019-028 37 Heiman Street Kiah Group Inc. c/o Sean O'Neill The owner/applicant is proposing a lot severance. The Committee of Adjustment previously granted provisional consent approval to create this lot in March 2018 via application B2018-023. Regional Comments: Community Planning: Regional Staff require the owner/applicant to submit the required consent review fee of $350.00 for the creation of a new lot. Water Services: The subject property is located in Kitchener Zone 4 with a static hydraulic grade line of 384 mASL. Any development with a finished road elevation below 327.8 mASL will require individual pressure reducing devices on each water service in accordance with Section B.2.4.7 of the Design Guidelines and Supplemental Specifications for Municipal Services for January 2019. Regional staff has no objection to the application, subject to the following conditions of approval: 1) That prior to final approval, the owner/applicant submit payment to the Region of Waterloo, the Consent Application Review Fee of $350.00. B2019-029 4278 King Street East Sportsworld Crossing Inc. The owner/applicant is proposing to a lot severance. The proposed severed lot will include the existing office building and parking lot and the proposed retained lot will remain vacant for future commercial uses. The owner/applicant also requires an easement for shared use of the existing driveway. Document Number: 3051281 Version: 1 Regional Comments: Community Planning: Regional Staff require the owner/applicant to submit the required consent review fee of $350.00 for the creation of a new lot. Noise: The owner/applicant will be required to enter into an agreement with the Region to submit a detailed Environmental/Stationary Noise Study and secure its implementation prior to Site Plan approval for any proposed development on the retained lands (Parcel B). The Assessment must address the possible impact of road traffic on any proposed development. In addition the Assessment must address the possible impact generated by the proposed development on all noise -sensitive uses in the vicinity and on the development itself, as well as any off-site noise sources identified by the noise consultant that may have an impact on the proposed development. The owner/applicant is required to enter into an agreement with the Region to complete the noise study prior to Site Plan and once approved amend/enter into a new agreement to implement the recommendations of that study. Regional Road Dedication: While no further road widening dedication is required along Regional Road 08 (King Street East) in accordance with the designated road width provided in Schedule `A' of the Regional Official Plan (ROP), please be advised that the King Street East corridor has been identified as the Region of Waterloo Council Endorsed, Preferred Option for Stage 2 of the Region's Light Rail Transit (ION). Under the ION Stage 2 re -construction process, further property dedications may be required in association with that project. For more information regarding the Region of Waterloo ION Stage 2 project please consult the Region of Waterloo website. (https://rapidtransit. regionofwaterloo.ca/en/stage21ON/stage2ion.asp) Access Permit/TIS/Access Regulation: The subject property currently has a right -in, right -out vehicular access to King Street East which also connects internally to the #4220 King Street East property. A new mutual shared access at the northwest property limits along with a mutual shared access easement between the properties owners intended to use the new relocated access will be required. The existing right -in, right -out access on King Street East will be closed. Document Number: 3051281 Version: 1 A Regional Road Access Permit application with an application fee of $230 will be required for the proposed access re -location and the closure of the existing access. The access permit application is available at: https://www.regionofwaterloo.ca/en/resources/Access Perm it-access.pdf. No other direct access to King Street East would be allowed to the retained lands. Regional Road Reconstruction — Please be advised that this section of King Street East is scheduled for re -construction in 2021 & 2022 according to the Region of Waterloo 10 - Year Transportation Capital Program. For more information on this project please contact Mr. William Gilbert at 519-575-4603. Stormwater Management: Regional Staff would note that a detailed SWM management report would be required for any development on the proposed severed and retained lots. Regional staff has no objection to the applications, subject to the following conditions of approval: 1) That prior to final approval, the owner/applicant submit payment to the Region of Waterloo, the Consent Application Review Fee of $350.00. 2) That prior to final approval, the owner/applicant enter into an agreement with the Region of Waterloo to submit a detailed Environmental and Stationary Noise Study prior to Site Plan approval for any proposed development on the retained lands. 3) That prior to final approval, the owner/applicant obtain an access permit(s) to the satisfaction of the Region of Waterloo. B2019-030 and B2019-031 452 and 256 Prospect Avenue William Wirtz The owner/applicant is proposing to sever the rear yard of 452 Prospect Avenue and add the severed portion to 456 Prospect Avenue. Then owner/applicant also would simultaneously sever the rear yard of 456 Prospect Avenue, including the added portion to create a new lot fronting on Broadview Avenue. Regional Comments: Community Planning: Regional Staff require the owner/applicant to submit the required consent review fee of $350.00 for the creation of a new lot. Document Number: 3051281 Version: 1 Regional staff has no objection to the applications, subject to the following conditions of approval: 1) That prior to final approval, the owner/applicant submit payment to the Region of Waterloo, the Consent Application Review Fee of $350.00. B2019-032 to B2019-042 78, 84, 86, 94, 104, 112, 114, Activa Holdings Inc. 122 Monarch Woods Drive The owner/applicant is proposing easements to provide access to the rear yard for residents. Regional staff has no objection to the applications. B2019-043 to B2019-050 110, 116, 118, 124, 126, 132, Activa Holdings Inc. 134,140 Ian Ormston Drive The owner/applicant is proposing easements to provide access to the rear yard for residents. Regional staff has no objection to the applications. CC2019-005 to CC2019-007 25 and 31 Fourth Avenue Lino and Angela Santarosa The owner/applicant has requested revisions to the proposed conditions as a result of the current ownership of the subject parcels and the timing of clearing certain conditions. The proposed consent applications are to facilitate future development plans for the two existing lots to become four lots. In order to close proposed transactions, the conditions of approval are required to be amended. Regional Comments: Regional Staff have no concerns as the proposed changes are to City of Kitchener conditions. Regional Staff had no concerns with the proposed applications B2019-002 to B2019-004 and the Regional condition for the consent review fee is not proposed to be changed. Regional staff has no objection to the subject applications. Document Number: 3051281 Version: 1 General Comments Any future development on the lands subject to the above -noted consent application(s) will be subject to the provisions of Regional Development Charge By-law 14-046 or any successor thereof. Please accept this letter as our request for a copy of the staff reports, decisions and minutes pertaining to each of the consent applications noted above. Should you require Regional Staff to be in attendance at the meeting or have any questions, please do not hesitate to contact the undersigned. Yours truly, Matthew Colley Planner Document Number: 3051281 Version: 1 Region of Waterloo July 05, 2019 Holly Dyson City of Kitchener 200 King Street West P.O. Box 1118 Kitchener, ON N2G 4G7 Dear Ms. Dyson: PLANNING, DEVELOPMENT AND LEGISLATIVE SERVICES 150 Frederick Street, Sth Floor Kitchener ON N2G 4A Canada Telephone: 519-575-4400 TTY: 519-575-4608 Fax: 519-575-4449 www. reg i o n ofwate r l o o. ca File No.: D20-20/VAR KIT GEN (7) /08 KING KIT, SPORTSWORLD CROSSING AND CHRISTIAN HORIZONS (10, 11) /12, Charlie Ormston Re: Committee of Adjustment Meeting on July 16, 2019, City of Kitchener Regional staff has reviewed the following Committee of Adjustment applications and have following comments: 1. SG 2019-014 — 150 Pioneer Drive — No Concerns. 2. SG 2019-015 — 2960 Kingsway Drive— No Concerns. 3. A 2019-059 — 364 Heritage Drive — No Concerns. 4. A 2019-060 — 72 Archer Place — No Concerns. 5. A 2019-061 — 15 Peter Street — No Concerns. 6. A 2019-062 — 920 Keewatin Place — No Concerns. 7. A 2019-063 — 4278 King Street East — No Concerns. 8. A 2019-064 — 452 Prospect Avenue — No Concerns. 9. A 2019-065 — 456 Prospect Avenue — No Concerns. 10.A 2019-066 to 073 — 74 to 122 Monarch Woods Drive — No Concerns. 11.A 2019-074 to 081 — 110 to 140 Ian Ormston Drive — No Concerns. 12.A 2019-082 — 83 Elmsdale Drive — No Concerns. Please be advised that any development on the subject lands is subject to the provisions of the Regional Development Charge By-law 14-046 or any successor thereof and may require payment of Regional Development Charges for these developments prior to the issuance of a building permit. The comments contained in this letter pertain to the Application numbers listed. If a site is subject to more than one application, additional comments may apply. Please forward any decisions on the above mentioned Application numbers to the undersigned. Document Number: 3050713 Page 1 of 2 Yours Truly, Joginder Bhatia Transportation Planner (519) 575-4500 Ext 3867 Grand River Conservation Authority 400 Clyde Road, P.O. Box 729 Resource Management Division Cambridge, Ontario N 1 R 5W6 Trisha Hughes, Resource Planner Phone: (519) 621-2761 ext. 2319 E-mail: thughes(u-)grandriver.ca PLAN REVIEW REPORT: City of Kitchener Holly Dyson DATE: July 5, 2019 RE: Applications for Minor Variance: YOUR FILE: See below SG 2019-015 2960 Kingsway Drive A 2019-059 364 Heritage Drive A 2019-060 72 Archer Place A 2019-061 15 Peter Street A 2019-062 920 Keenwatin Place A 2019-063 A 2019-064 A 2019-065 A 2019-066 to 073 A 2019-074 to 081 A 2019-082 4278 King Street East 452 Prospect Avenue 456 Prospect Avenue 78, 84, 86, 94, 104, 112, 110, 116, 118, 124, 126, 83 Elmsdale Drive Applications for Consent: 114, 122 Monarch Woods Drive 132, 134, 140 Ian Ormston Drive B 2019-025 4283 King Street East B 2019-026 4285 King Street East B 2019-029 4278 King Street East B 2019-030 452 Prospect Avenue B 2019-031 456 Prospect Avenue B 2019-032 to 042 78, 84, 86, 94, 104, 112, 114, 122 Monarch Woods Drive B 2019-043 to 050 110, 116, 118, 124, 126, 132, 134, 140 Ian Ormston Drive B 2019-051 to 054 83 Elmsdale Drive GRCA COMMENT: The above noted applications are located outside the Grand River Conservation Authority areas of interest. As such, we will not undertake a review of the applications and plan review fees will not be required. If you have any questions, or require additional information, please contact me. Sincerely, Trisha Hughes Resource Planner Grand River Conservation Authority xThese comments are respectfully submitted as advice and reflect resource concerns within the scope and mandate of the Page 1 of 1 Grand River Conservation Authority