HomeMy WebLinkAboutDSD-2025-116 - A 2025-024 - 507 Stirling Avenue South
Development Services Department www.kitchener.ca
REPORT TO: Committee of Adjustment
DATE OF MEETING: March 18, 2025
SUBMITTED BY: Tina Malone-Wright, Manager, Development Approvals
519-783-8913
PREPARED BY: Adiva Saadat, Planner, 519-783-7658
WARD(S) INVOLVED: Ward 9
DATE OF REPORT: March 4, 2025
REPORT NO.: DSD-2025-116
SUBJECT: Minor Variance Application A2025-024 507 Stirling Ave. S.
RECOMMENDATION:
A. Minor Variance Application A2025-024 507 Stirling Avenue South
That Minor Variance Application A2025-024 for 507 Stirling Avenue South
requesting relief from the following sections of Zoning By-law 2019-051:
i) Section 4.1 d), to permit an accessory structure to have a building height, to
the underside of the fascia, of 4 metres instead of the maximum permitted 3
metres;
ii) Section 7.3, Table 7-2, to permit a lot coverage of 18% instead of the maximum
permitted 15%;
to facilitate the construction of a new accessory building and Additional Dwelling
Unit (ADU)(Detached) in the rear yard of the subject property generally in
accordance with drawings prepared by KS Consulting & Design, dated January 30,
2025, BE APPROVED, subject to the following conditions:
1. That the Owner provides confirmation, to the satisfaction of the Director of
Engineering Services, that the existing services can support the proposed
additional demand prior to an application for a Building Permit being
received. If the demand cannot be supported, the Owner shall make an
Application through the Off-Site Works Process, to the satisfaction of the
Director of Engineering Services.
2. That the Owner acknowledges that any new driveways or widenings to existing
driveways are to be built to City of Kitchener standards and that the
Owner confirms, to the satisfaction of the Director of Engineering Services, if
*** This information is available in accessible formats upon request. ***
Please call 519-741-2345 or TTY 1-866-969-9994 for assistance.
an application for a Curb Cutting/Driveway Widening Permit is required prior to
an application for a Building Permit being received.
3. That the Owner shall:
a) Prepare a Tree Preservation Plan for the Subject Lands, in accordance
necessary, implemented prior to any grading, servicing, tree removal or
the issuance of Demolition and/or Building Permits. Such plans shall
include, among other matters, the identification of a proposed building
envelope/work zone, a landscaped area and the vegetation to be
preserved. If necessary, the plan shall include required mitigation and/or
compensation measures.
b) That the Owner further agrees to implement the approved plan. No
changes to the said plan shall be granted except with the prior approval of
B. Minor Variance Application A2025-024 507 Stirling Avenue South
That Minor Variance Application A2025-024 for 507 Stirling Avenue South
requesting relief from the following section of Zoning By-law 2019-051:
i) Section 4.12.3 n) to permit a required unobstructed walkway of 1.1 metres to
share a driveway whereas the by-law does not permit this;
to facilitate the construction of a new Additional Dwelling Unit (ADU)(Detached) in
the rear yard of the subject property generally in accordance with drawings
prepared by KS Consulting & Design, dated January 30, 2025, BE REFUSED.
REPORT HIGHLIGHTS:
The purpose of this report is to review a minor variance application to permit the
construction of a new accessory building and Additional Dwelling Unit
(ADU)(Detached) in the rear yard
The key finding of this report is that two of the three requested minor variances meet
all four tests of the Planning Act. The variance for the shared unobstructed walkway
and the driveway does not meet all four tests of the Planning Act.
There are no financial implications.
Community engagement included a notice sign being placed on the property advising
that a Committee of Adjustment application has been received, notice of the
application was mailed to all property owners within 30 metres of the subject property
agenda in advance of the
Committee of Adjustment meeting.
This report supports the delivery of core services.
BACKGROUND:
The subject property is located on the north-east side of Stirling Avenue South and Lorne
Avenue. It is in the Southdaleneighbourhood which is primarily comprised of low-rise
residential uses.
Figure 1: Location Map 507 Stirling Avenue South (Outlined in Red)
Community AreasUrban Structure and is
designated Rise Residential
--law 2019-
051.
The purpose of the application is to review a minor variance application to facilitatethe
construction of a new accessory building and Additional Dwelling Unit (ADU)(Detached) in
the rear yardof the subject property.The applicant is seeking three variances:
1.The requested variance to permit a1.1 metre wide shared walkway is to provide
accessto the ADUover the driveway. Planning staff advised the applicant to relocate
the walkway to the other side of the primary dwellingto meet zoning requirements.
Despite the advice, the applicant indicated that they wanted to proceed with the minor
variance application to avoid relocating the air conditioner and gas meterin this side
yard.
2.The variance to permit 4 metres fascia height is requested to accommodate the
height of the proposed accessory building.
3.The variance to permit a lot coverage of 18% is to facilitate the construction ofboth
the ADU and the accessory building as the combined lot coverage exceeds the
permitted lot coverage.
Variance for 4m fascia height
Figure 2: Requested Variance for Accessory Building
Figure 3: Rear Elevation of Proposed Structures
Figure 4: Left Elevation of Proposed Structures
Figure 5: Right Elevation of Proposed Structures
Figure 6: Floor Plan of Proposed Structures
Variance for1.1m shared walkway
Figure 7: Requested Variances SitePlan
Planning Staff conducted a site visit on February 27, 2025
Figure 8: Existing Site Conditions as of February 27, 2025
Figure 9: Proposed Shared Walkway and Driveway (West Side)
Figure 10: East Side Interior Side Yard
Figure 11: Rear Yard of the Property
REPORT:
Planning Comments:
In considering the four tests for the minor variances as outlined in Section 45(1) of the
Planning Act, R.S.O, 1990 Chap. P 13, as amended, Planning staff offers the following
comments:
General Intent of the Official Plan
Variance for the Walkway
Urban Design Policies 11.C.1.14 and 11.C.1.15
emphasize community and site design to prioritize efficient emergency response, fire
prevention and public safety.
11.C.1.14. Where feasible and in compliance with the other policies of this Plan,
the City will ensure that the efficiency of emergency medical, fire, and
police services be considered in the design of communities,
neighbourhoods and individual sites.
11.C.1.15. Development applications will be reviewed to ensure that they are
designed to accommodate fire prevention and timely emergency
response.
Also, the Urban Design Manual prioritize pedestrian safety by mitigating potential
conflicts with pedestrians and vehicles. The proposed 1.1 metre walkway is proposed to
be shared with the driveway will not be unobstructed and may block emergency services
access. Given this potential conflict, this variance will not meet the intent of the Official
Plan.
Variances for the Accessory Building Fascia Height and Lot Coverage
This
land use designation places emphasis on compatibility of building form with respect to
massing, scale, and design in order to support the successful integration of different
housing and building types. The proposed accessory building use of the property conforms
to the land use designation and is a desirable addition to a residential property. It is the
opinion of staff the requested variance meets the general intent of the Official Plan.
General Intent of the Zoning By-law
Variance for the Walkway
The general intent of the Zoning By-law requiring unobstructed walkway is to ensure safe,
accessible, and efficient movement for occupants of the ADU and emergency services can
access the site efficiently. This includes ensuring that pathways are clear of physical
obstacles, such as parked vehicles, debris, or structures, so people can walk freely without
risk of injury. The provided walkway is not unobstructed, the Zoning By-law definition
which states that the walkway
limited to: stairs, decks and porches (except those which form part of the path of travel to
driveway encumber the walkway. Staff is in opinion that the proposed variance does not
meet the general intent of the Zoning By-law.
Variance for the Accessory Building Fascia Height
The intent of the maximum height to the underside of the fascia is to ensure that
accessory building is not excessive in height and to ensure neighbouring properties do not
have adverse impacts from large rear yard structures. The accessory building will be used
strictly for vehicle storage, ensuring that it will not create any privacy concern to the
neighbouring properties. Staff is of the opinion that the requested variance meets the
general intent of the Zoning By-law.
Variance for Increased Lot Coverage for Accessory Building and Additional dwelling Unit
(ADU) (Detached)
The intent of the maximum lot coverage is to ensure that accessory buildings remain
secondary to the primary building. If you combine the lot coverage of both the accessory
building and the ADU it exceeds the maximum permitted 15% as per Section 7.3, Table 7-
2 by 3% or 15 square metres. Despite the combined exceeded lot coverage, the size of
the accessory building and ADU is under the maximum permitted building footprint of 80
square metres. Staff is of opinion that the variance meets the general intent of the Zoning
By-law by remaining secondary and accessory to the primary building.
Is/Are the Effects of the Variance(s) Minor?
Variance for the Walkway
Staff is in opinion that the effects of the variance are not minor in nature. The shared
driveway obstructs the walkway, making it inaccessible for emergency vehicles causing a
safety issue. As a result of the variance, there will be a conflict between pedestrian and
vehicle use as neither walkway nor the driveway will be able to function independently.
Variance for the Accessory Building Fascia Height
The effects of the variance is minor in nature as there are no significant impact on the
neighbouring properties. The accessory building with the proposed increased fascia height
maintains a sufficient setback of 11.6 metres from the rear lot line which mitigates privacy
concerns for the neighbouring properties as well as no windows to overlook the
neighbouring property while using the accessory building.
Variance for Increased Lot Coverage for Accessory Building and Additional dwelling Unit
(ADU) (Detached)
The variance is minor in nature. The combined 15 square metres increased lot coverage is
not noticeable when compared to the overall size of the structures relative to the lot. The
ADU and garage are located at the far rear of the property. The increased lot coverage is
not noticeable from the streetscape and does not impact the visual appearance of the
neighbourhood.
Is/Are the Variance(s) Desirable for The Appropriate Development or Use of the Land,
Building and/or Structure?
Variance for the Walkway
The variance is not desirable for the use of the land. The design creates a conflict between
pedestrian and vehicle on site and fails to support a walkable community without providing
an unobstructed connection to the street. Occupants and emergency services will not be
able to navigate safely which compromises the usability of the land.
Variance for the Accessory Building Fascia Height
The variance is appropriate for the development and use of the land as it will increase the
usability of the accessory building on the subject property. The increased fascia height will
allow the accessory building to be more functional and allow for efficient storage of
vehicles.
Variance for Increased Lot Coverage for Accessory Building and Additional dwelling Unit
(ADU) (Detached)
The variance for an increased lot coverage is desirable and appropriate use of the land as
it facilitates the construction of an accessory building and an additional dwelling unit
(ADU). The increased lot coverage will allow for efficient vehicle storage and improve the
usability of the land by accommodating the ADU which contributes to the overall
functionality and usability of the property.
Fire Services Comments:
With no legal mechanism to enforce no-parkingin the driveway where the walkway is
proposed to be located, fire would not support the combined walkway and driveway. The
proposal does not comply with the Emergency Services Policy because the ADU is
approximately 37 metres from the principal entrance, whereas the emergency service
policy restricts this distance to a maximum of 30 metres for dwelling units with direct
access to the outside from the unit. If the exit/principal entrance is shared by two or more
units that distance is reduced to 15 metres.
Environmental Planning Comments:
No natural heritage. Trees may be impacted in the rear yard by ADU construction.
Accordingly, it is recommended that the standard Tree Management Condition be added
as a Condition of the Minor Variance Application to ensure there are no negative impacts
to trees on adjacent properties.
1. That the Owner shall:
a) Prepare a Tree Preservation Plan for the Subject Lands, in accordance with the
prior to any grading, servicing, tree removal or the issuance of Demolition and/or
Building Permits. Such plans shall include, among other matters, the identification
of a proposed building envelope/work zone, a landscaped area and the vegetation
to be preserved. If necessary, the plan shall include required mitigation and or
compensation measures.
b) That the Owner further agrees to implement the approved plan. No changes to the
Plans.
Heritage Planning Comments:
No comments or concerns.
Building Division Comments:
The Building Division has no objections to the proposed variance provided building permits
for the detached ADU and detached garage is obtained prior to construction. Please contact
the Building Division at building@kitchener.ca with any questions.
Engineering Division Comments:
1. That the Owner provides confirmation, to the satisfaction of the Director of Engineering
Services, that the existing services can support the proposed additional demand prior
to an application for a Building Permit being received. If the demand cannot be
supported, the Owner shall make an Application through the Off-Site Works
Process, to the satisfaction of the Director of Engineering.
2. That the Owner acknowledges that any new driveways or widenings to existing
driveways are to be built to City of Kitchener standards and that the Owner confirms,
to the satisfaction of the Director of Engineering Services, if an application for a Curb
Cutting/Driveway Widening Permit is required prior to an application for a Building
Permit being received.
Parks and Cemeteries/Forestry Division Comments:
No comments or concerns.
Transportation Planning Comments:
Transportation Services does not support the proposed garage or parking space location
at the rear of the property. Vehicles accessing the parking space or garage must drive
over the walkway, and occupants may not be aware to keep this walkway unobstructed of
parked vehicles. Obstructions of the walkway may block emergency services accessing
the ADU.
STRATEGIC PLAN ALIGNMENT:
This report supports the delivery of core services.
FINANCIAL IMPLICATIONS:
Capital Budget The recommendation has no impact on the Capital Budget.
Operating Budget The recommendation has no impact on the Operating Budget.
COMMUNITY ENGAGEMENT:
INFORM
of the Committee of Adjustment meeting. A notice sign was placed on the property
advising that a Committee of Adjustment application has been received. The sign advises
Planning Division. A notice of the application was mailed to all property owners within 30
metres of the subject property.
PREVIOUS REPORTS/AUTHORITIES:
Planning Act
Provincial Planning Statement (PPS 2024)
Regional Official Plan
Official Plan (2014)
Zoning By-law 2019-051
March 4, 2025
Connie Owen
City of Kitchener File No.: D20-20/
200 King Street West VAR KIT GEN
P.O. Box 1118
Kitchener, ON N2G 4G7
Subject: Committee of Adjustment Meeting March 18, 2025, City of Kitchener
Regional staff has reviewed the following Committee of Adjustment applications and
have the following comments:
1) A 2025 013 160 Grand River Boulevard - No Concerns
2) A 2025 014 51 Meadowridge Street - No Concerns
3) A 2025 015 1180 Union Street - No Concerns
4) A 2025 016 45-53 Courtland Avenue East - No Concerns
5) A 2025 017 1157 & 1175 Weber Street East- No Concerns
6) A 2025 018 - 60 Wellington Street North - No Concerns
7) A 2025 019 - 114 Madison Avenue South- No Concerns
8) A 2025 020 - 15 Palace Street - No Concerns
9) A 2025 - 021 - 2880 King Street East No Concerns
10) A 2025-022 - 25 Haldimand Street - No Concerns
11) A 2025-023 - 140 Byron Avenue No Concerns
12) A 2025-024 - 507 Stirling Avenue South No Concerns
13) A 2025-025 - 93-95 Kinzie Avenue No Concerns
14) A 2025-026 - 250 Frederick Street No Concerns
15) A 2025-027- 13 Chicopee Park Court No Concerns
16) A 2024-096 - 165 Fairway Road North No Concerns
5ƚĭǒƒĻƓƷ bǒƒĬĻƩʹ ЍВЋЉЍВЍ ĻƩƭźƚƓʹ Њ
Please be advised that any development on the subject lands is subject to the
provisions of the Regional Development Charge By-law 19-037 or any successor
thereof and may require payment of Regional Development Charges for these
developments prior to the issuance of a building permit.
The comments contained in this letter pertain to the Application numbers listed. If a site
is subject to more than one application, additional comments may apply.
Please forward any decisions on the above-mentioned Application numbers to the
undersigned.
Yours Truly,
Tanikia Kinear, C.E.T.
Senior Transportation Planner
(519) 897-5691
5ƚĭǒƒĻƓƷ bǒƒĬĻƩʹ ЍВЋЉЍВЍ ĻƩƭźƚƓʹ Њ
March 3, 2025 via email
Marilyn Mills
Secretary-Treasurer
Committee of Adjustment
City of Kitchener
200 King Street West
Kitchener, ON, N2G 4G7
Dear Marilyn Mills,
Re: Committee of Adjustment Meeting March 18, 2025
Applications for Minor Variance
A 2024-096 165 Fairway Road North
A 2025-013 160 Grand River Boulevard
A 2025-014 51 Meadowridge Street
A 2025-015 1180 Union Street
A 2025-016 45-53 Courtland Avenue East
A 2025-017 1157-1175 Weber Street East
A 2025-018 60 Wellington Street North
A 2025-019 114 Madison Avenue South
A 2025-020 15 Palace Street
A 2025-021 2880 King Street East
A 2025-022 25 Haldimand Street
A 2025-023 140 Byron Avenue
A 2025-024 507 Stirling Avenue South
A 2025-025 93-95 Kinzie Avenue
A 2025-026 250 Frederick Street
A 2025-027 13 Chicopee Park Court
Applications for Consent
B 2025-006 142 Carson Drive
B 2025-007 13 Chicopee Park Court
B 2025-008 11a & 11b Chicopee Park Court
Grand River Conservation Authority (GRCA) staff has reviewed the above-noted
applications.
GRCA has no objection to the approval of the above applications. The subject properties do
not contain any natural hazards such as watercourses, floodplains, shorelines, wetlands, or
valley slopes. The properties are not subject to Ontario Regulation 41/24 and, therefore, a
permission from GRCA is not required.
Should you haveany questions, please contact meataherreman@grandriver.caor 519-
621-2763 ext. 2228.
Sincerely,
Andrew Herreman,CPT
Resource Planning Technician
Grand River Conservation Authority