HomeMy WebLinkAboutDSD-2026-070 - Heritage Permit Application HPA-2026-V-004 - 98 College Street
Development Services Department www.kitchener.ca
REPORT TO: Heritage Kitchener
DATE OF MEETING: March 3, 2026
SUBMITTED BY: Garett Stevenson, Director of Development and Housing Approvals,
519-783-8922
PREPARED BY: Victoria Grohn, Heritage Planner, 519-783-8912
WARD(S) INVOLVED: Ward 10
DATE OF REPORT: February 2, 2026
REPORT NO.: DSD-2026-070
SUBJECT: Heritage Permit Application HPA-2026-V-004
98 College Street
Building Conversion and Associated Exterior Alterations
RECOMMENDATION:
That pursuant to Section 42 of the Ontario Heritage Act, Heritage Permit Application
HPA-2026-V-004 be approved to permit the construction of a fire escape, alterations
to window and door openings, and the construction of a new rear roof dormer at the
property municipally addressed as 98 College Street, in accordance with the
supplementary information submitted with this application and subject to the
following condition:
1. That the final building permit drawings be reviewed, and heritage
clearance be provided by Heritage Planning staff prior to the issuance of a
building permit.
REPORT HIGHLIGHTS:
The purpose of this report is to present Heritage Planning staffÓs recommendation
regarding the proposed building conversion at 98 College Street and associated
exterior alterations, including the construction of a fire escape, alterations to window
and door openings, and the construction of a rear roof dormer.
The key finding of this report is that the proposed alterations associated with the
conversion of the existing building to eight (8) dwelling units will not adversely impact
the cultural heritage value or interest of the property municipally addressed as 98
College Street, the College Street streetscape, or the Civic Centre Neighbourhood
Heritage Conservation district.
There are no financial implications associate with this report.
Community engagement include d consultation with the CityÓs Heritage Kitchener
Committee.
This report supports the delivery of core services.
*** This information is available in accessible formats upon request. ***
Please call 519-741-2345 or TTY 1-866-969-9994 for assistance.
Page 23 of 282
This heritage permit application is not delegated to Heritage Planning staff because
the Civic Centre Neighbourhood Heritage Conservation District Plan identifies
conversions with exterior alterations visible from the street or other public space as
works requiring Council (Heritage Kitchener review) approval. Additionally, the Plan
includes policies and guidelines related to fire escapes and window and door
alterations, and the proposal does not fully comply with those requirements.
BACKGROUND:
The Development Services Department is in receipt of Heritage Permit Application HPA-
2026-V-004 for the property municipally addressed as 98 College Street. The application
is for the construction of a fire escape, alterations to windows and doors, and the
construction of a new rear roof dormer, which are all works associated with the proposed
building conversion to eight (8) residential units.
The subject property is located on the west side of College Street between Weber Street
West and Ahrens Street West. It is located within the Civic Centre Neighbourhood
Heritage Conservation District (CCNHCD) and therefore designated under Part V of the
Ontario Heritage Act. It is identified as a Group ÒBÓ building.
The CCNHCD Plan indicates that building conversions with exterior alterations that are
visible from the street or other public space requires a Heritage Permit Application and
Council approval (Heritage Kitchener review). Furthermore, Chapter 642 of the CityÓs
Municipal Code pertaining to Delegated Approval Authority for the alteration of Part IV and
Part V designated properties indicates that applications that have the potential for
significant impact on cultural heritage value of the property as identified in the
conservation district plan are to be reviewed by Heritage Kitchener. While the proposed
alterations are not anticipated to have significant impact on the property, the alterations
proposed, particularly the exterior fire escape, are not in compliance with the policies
contained in the CCNHCD Plan and warrants additional review.
Figure 1: Location Map
Page 24 of 282
REPORT:
The subject property contains a 2 ½-storey c.1905 brick building constructed in the
Georgian architectural style.
Figure 2: Front Façade of 98 College Street
Proposal
Heritage Permit Application HPA-2026-V-004 is a proposal for exterior alterations to the
existing building to facilitate its conversion to eight (8) residential units. The exterior
alterations include: the construction of a fire escape, alterations to window and door
openings, and the construction of a new rear roof dormer.
Construction of Fire Escape
To facilitate the conversion of the existing building to eight (8) residential units, and in
compliance with the Ontario Building Code (OBC), a second means of egress with access
at grade is required for the upper-level units. The building has been demised in way that
retains key interior millwork, where feasible. Given the age of the existing building (c.
1905), the OBC permits the use of fire escapes as an option. The owner/applicant chose
this option over a second enclosed stairway because it maintains a smaller footprint and
reduces exterior impact to the building.
The CCNHCD Plan outlines the following policy regarding building conversions and
associated alterations:
Page 25 of 282
3.3.2 Alterations to Existing Buildings
3.3.2.(b) Structural alterations to the exterior of buildings are not permitted in the
event of residential conversions. Any exterior stairs or fire escapes are to be
enclosed and kept away from the façade of the structure.
The purpose of this policy is to ensure that in the event of building conversions within the
CCNHCD, that the low-rise profile of the building is maintained.
While the proposal outlined in HPA-2026-V-004 contemplates the construction of a non-
enclosed fire escape, consideration has been given by the owner/applicant to minimize
impacts to the exterior of the building, where feasible, while maintaining the existing profile
of the building. The fire escape is proposed to be constructed from black power coated
metal to complement the existing wrought iron features of the building. The fire escape is
designed with dimensions as close to the OBC minimum requirements as possible to
facilitate exit purposes only and is not intended for or contemplated as amenity space on
the property. The fire escape is proposed to be supported by eight (8) posts; four (4) of
which are affixed to new footings at grade while the other four (4) are anchored into the
bricks. Lastly, the fire escape is located towards the rear of the building and does not
impact the front façade, which conforms to the recommended practice of the CCNHCD
Plan outlined in section 6.8.1.
Figure 3: Proposed Exterior Fire Escape
Alteration to Window and Door Openings
To facilitate the conversion of the existing building, there are several windows and doors
on the north (right), south (left), and rear (west) elevations. These changes are to enlarge
existing windows to provide proper egress from the residential units or to provide an
additional ground level access. While the CCNHCD Plan notes that these are works not
requiring Council approval, Heritage Planning staff are highlighting the window and door
alterations because the CCNHCD Plan does note in the recommended practices and
design guidelines for building conversions that original door and window locations should
not be blocked or removed.
Page 26 of 282
Figures 4 & 5: Proposed Window and Door Alterations
Construction Rear Roof Dormer
To facilitate the conversion of the existing building, a new roof dormer is proposed to be
constructed on the rear façade of the dwelling. While the construction of the new roof
dormer is an alteration to the original roofline of the building, it is located at the rear of the
property, away from public view. Additionally, the new roof dormer is similar to the existing
roof dormer on the principal façade.
6.8.1 Recommended Practices and Design Guidelines (Building Conversions)
Avoid altering the streetscape façade of the building. Try to provide access to
individual apartments and offices from the interior of the building. If this is not
feasible, new entrances should be located to the side or rear of the dwelling.
o This practice/guideline is met as new entrances are located to the side of
the dwelling.
Page 27 of 282
If exterior stairs are required for access or emergency exit purposes, they should
be situated at the rear or side of the dwelling away from view, using materials and
construction methods that are compatible with the original building design.
o This practice/guideline is met as the exterior stairs are located at the side
and rear, and the materials and construction methods are compatible with
the design of the dwelling.
Do not block up or remove original door and window locations.
o The windows proposed to be altered are basement windows on non-
principal facades. The location of the windows is not changing; they are
proposed to be enlarged to comply with the Ontario Building Code. The
removal of the window on the right (north) elevation to accommodate two (2)
new doors is not a character-defining feature of the building and is located
away from the principal façade. The door opening on the left (south)
elevation is proposed to be relocated at grade and will not be visible from
the public right-of-way. While this practice/guideline is not met, the proposed
window and door alterations are located away from the principal façade and
have been considered to result in the least disruption to the historic fabric of
the building while still complying with Ontario Building Code requirements.
Locate additional utility meters in an inconspicuous, but still accessible location at
the rear or side of the building.
o This practice/guideline is met.
Front yard or boulevard parking is discouraged unless unavoidable and permitted
by zoning regulations.
o This practice/guideline is met as no front yard or boulevard parking is
proposed.
If additional parking must be provided, it should be located at the rear or side of the
building with appropriate landscaping or fencing provided to screen it from the
street and adjacent neighbours.
o This practice/guideline is met.
Heritage Planning Comments
In reviewing the merits of the application, Heritage Planning staff note the following:
The subject property is located within the CCNHCD and is designated under Part V
of the Ontario Heritage Act.
The subject property is classified as District Significance ÒBÓ meaning it is a building
of importance within the CCNHCD, per the 2006 CCNHCD Study.
The proposed fire escape maintains a smaller footprint and reduces exterior impact
on the building, as opposed to the construction of a second enclosed stairway.
The proposed fire escape will be partially affixed to the brick of the building. While
this is a semi to permanent alteration, the open stairway will not cover up
architectural details or result in the removal of prominent architectural details of the
building.
The proposed fire escape will be black powder coated metal to be more visually
compatible with the existing building.
Page 28 of 282
The proposed fire escape conforms to the recommended practice of the CCNHCD
Plan regarding the location, material, and construction method of exterior stairs
required for access or emergency purposes.
The proposed window and door replacements/removals are not impacting
character-defining features of the building, are not located on the principal façade
and are required for Ontario Building Code compliance.
The proposed new roof dormer is located at the rear of the building away from
public view and is similar to the existing roof dormer on the principal façade.
The prosed work is generally in compliance with the CCNHCD Plan guidelines for
building conversions.
The proposed work will not have a negative impact on the integrity or the heritage
character of the building, the College Street streetscape, or the CCNHCD.
In accordance with the Heritage Permit Application form, the approval of any application
under the Ontario Heritage Act shall not be a waiver of any of the provisions of any by-law
of the City of Kitchener or legislation, including, but not limited to, the requirements of the
Ontario Building Code and Zoning By-law. In this regard, staff confirm that a Building
Permit is required to undertake the outlined alterations to facilitate the conversion of this
building to eight (8) residential units.
STRATEGIC PLAN ALIGNMENT:
This report supports the delivery of core services.
FINANCIAL IMPLICATIONS:
Capital Budget Î The recommendation has no impact on the Capital Budget.
Operating Budget Î The recommendation has no impact on the Operating Budget.
COMMUNITY ENGAGEMENT:
INFORM Î This report has been posted to the CityÓs website with the agenda in advance
of the Heritage Kitchener committee meeting.
CONSULT Î The Heritage Kitchener Committee will be consulted regarding the subject
Heritage Permit Application.
PREVIOUS REPORTS/AUTHORITIES:
Ontario Heritage Act, 2022
Civic Centre Neighbourhood Heritage Conservation District Plan
REVIEWED BY: Sandro Bassanese, Manager of Site Plan
APPROVED BY: Justin Readman, General Manager, Development Services
ATTACHMENTS:
Attachment A Î Heritage Permit Application HPA-2026-V-004
Attachment B Î Supplementary Information
Page 29 of 282
Attachment C Î Heritage Permit Application Drawings
Page 30 of 282
98 College St Kitchener ON
Plan 401 pt lot 8
98 College Inc.
139 Dunbar Rd S
Waterloo ON N2L2E8
519-572-0980
eolsen@1928393.com
Andrew J. Vlcek
Martin Simmons Sweers Architects Inc.
200 - 113 Breithaupt St.
Kitchener / Ontario / N2G 5G9
(519) 404 - 5184
avlcek@mssarchitects.ca
Page 31 of 282
Refer to attached application letter
Refer to attached application letter
Refer to attached application letter
Refer to attached application letter
November 2026
May 2026
Victoria Grohn - Heritage Planner
Permit #: 25 130919
Page 32 of 282
01/26/26
Erik Olsen
Martin Simmons Sweers Architects
01/26/26
Page 33 of 282
Page 34 of 282
Page 35 of 282
Page 36 of 282
Page 37 of 282
Page 38 of 282
Page 39 of 282
Page 40 of 282
Page 41 of 282
Page 42 of 282
Page 43 of 282
Page 44 of 282
Page 45 of 282
Page 46 of 282
Page 47 of 282
Page 48 of 282
Page 49 of 282